                                                                                                                                                                                                         NOOSA COUNCIL                                                                                                    Site Preparation and Planting Notes:



       Determining the Radius of the TPZ (Tree Protection Zone)
                                                                                                                                                                                                         APPROVED PLAN                                                                                                    1. Weed spray 500mm circumference around stake (remove weeds).
                                                                                                                                                                                                                                                                                                                          2. Install 900mm hardwood garden stake spray painted red at plant location.
                                                                                                                                                                                                                                                                                                                          3. Install 1m wide weed mat per manufacturer's specifications.
       ·
       ·
           DBH (Diameter at Breast Height) - nominal trunk diameter at 1.4m above ground level
           TPZ should not be less than 2m nor greater than 15m (except where crown protection is required)                                                                                            RAL23/0021 & OPW23/0177                                                                                             4. Plant tubestock per detail below.
       ·   TPZ = DBH X 12
       ·
       ·
           TPZ of palms, other monocots, cycads and tree ferns should not be less than 1m
           Variations and encroachments to the TPZ in accordance with A.S. 4970-2009
                                                                                                                                                                                                            16 JAN 2024                                                                                                                                                                                            3x Bamboo stakes, triangularly spaced

                                                                                                                                                                                                                                                                                                                                                                                                                   Install 'Suregro' tree guards or
                                                                                                                                                                                                                                                                                                                                                                                                                   equivalent product as per
                                                                                                                                                                                                                                                                                                                                                                                                                   manufacturer's recommendations
                                                                                                                                                                                                                                                                                                                                                                                                                   (if required, confirm with site
                                                                                                                                                                  Timber Specification:                                                                                                                                                                     3x Tube Ø                                              superintendent and LA, contractor to
                                                                                                                                                                  Unseasoned hardwood, Class 1 Select Grade F17, ACQ or Tanalith E minimum H4 treatment,                                                                                                                                                           provide alternate pricing rate per tube)
                                                                                                                                                                  with one coat of timber coating.
                                                                                                                                                                                                           Galvanised timber                                                                                                                                                                                       Tubestock plant, refer to plant
                                                                                                                                                                                                           fixing screws, typ.                                                                                                                                                                                     schedule for species
                                                                                        Fluorescent orange 5.5k.g                                                                                                                                                                                                                                                                                                  Form shallow saucer shaped
                                                                                        barrier fencing mesh secured                                                                                                                                                                                                                                                                                               depression around plant base
                                                                                        / tied 100mm below top of star
                                            Measurement                                 pickets at 300mm centres                                                                                                                                                                                                                                                                                                   1m² pinned weed mat, typ., install per
                                            taken for DBH                                                                                                                                                                                                                                                                                                                                                          manufacturer's specifications
                                                                                        Yellow plastic capped
                                                          Fencing                                                                                                                                                                                                                                                                                                                                                  100mm deep organic as specified,
                                                                                        star pickets
                                                                                        painted yellow                                                             ELEVATION                                                                                                                                                                                                                                       minimum 50mm clear of plant stem
                                            Vegetation to                  1200mm
                          1.4m




                                            be protected
                                                                                            Ground line
                    Crown                  DBH                                                                                                                                                                                                                                                                                                                                                                     Cultivated subgrade and plant pit to 150mm
                                                                            600mm                                                                                                                1200mm, maximum
                    TPZ
                                                                                                                                                                   PLAN
        NOTES:
        ·  Protective fencing to be installed around the TPZ to the commencement of any site works
        ·  Protective fencing identifying the TPZ, to be visibly signed within the development site. Lettering to comply with                                     150mm x 50 mm timber edging                                                50mm x 25mm x 450mm                                                                                                                                                   Topsoil per specifications
           A.S.1319.                                                                                                                                                                                                                         hardwood peg
        ·  Fence posts and supports to have a diameter greater than 20mm, located clear of roots                                                                                                                                 20mm        @1200mm centres                                                                                                                                                       5 gram 'Agriform' tablet as specified.
        ·  Where tree protection fencing cannot be installed, trunk, branch and ground protection as specified by the project                                     Turf as specified                                                                                                                                                                                                                                Use phosphorus free tablets for
                                                                                                                                                                                                                                             Mulch as specified
           Arborist in accordance with A.S.4970-2009                                                                                                              2x hot dipped galvanised
                                                                                                                                                                                                                                                                                                                                                                                                                   Banksias, Callistemons and Grevilleas
        ·  Within TPZ, mulch to a depth of 50-100mm only for disturbed land                                                                                       triple grip screw to fix mitred
        ·  Maintenance of TPZ includes regular monitoring of soil moisture levels and weed removal by hand and controlled by                                      timber edging together,
                                                                                                                                                                                                                                                                                                                                                                                                                   Subgrade
           appropriate use of herbicide                                                                                                                           typical.
        ·  TPZs to be monitored, inspected and certified by the project Arborist
                                                                                                                                                                                                                  SECTION
        ·  Removal of tree protection measures at practical completion or as indicated by the project Arborist

            1              Tree and Vegetation Protection Detail                                                            N.T.S.                                     3           Hardwood Treated Garden Edge                                                   N.T.S.
           LD3             Typical Detail                                                                                                                            LD3           Typical Detail                                                                                                                             6           Tubestock Planting with Tree Guards and Weed Mat                                                                  N.T.S.

                                                                                                                                                                                                                                                                                                                             LD3          For Drainage Channel Revegetation where required - Typical Section


                                                                                                                                                                  NOTES:
                                                                                                                                                                  Ensure crown of rootball level is set higher than adjacent finished ground levels to prevent excessive ponding around rootball.                                           3x Tube Ø
                                                                                                                                                                  When footpath is adjacent to street tree install root barrier to footpath side of plant pit as per notes above.
                                                                                                                                                                                                                            1800


                                                                                                                                                                                                                                                                                                                                                                               Tubestock plant as specified
                                                                                                                                                                                                                                                                     Full and even crown, typical
                                                                                                                                                                                                                                                                     2 - 50mm x 50mm x 2400mm F14 hardwood
                                                                                                                                                                                                                                                                     centrally pointed non-treated stakes to be
       STREET TREE PLANTING DETAIL PLAN                                                                                                                                                                                                                              driven vertically into ground outside of the                                                              Form shallow saucer shaped depression
                                                                                                                                                                  50mm wide hessian tree ties                                                                        rootball and shall have a finished height lower                                                           around plant base
                                                                                                                                                                  wrapped loosely around trunk,                                                                      than the tree's lower lateral limbs
                                                                                                                                                                  then a figure 8 and secured to
                                                                                                                                                                  stake with galvanised nails or                                                                     Form shallow saucer shaped depression
                                                                                                             50mm x 150mm H4 F14 hardwood timber                  staples. Position tree tie between                                                                                                                                                                           100mm deep organic mulch as specified,
       Topsoil with mulch                                                                                    edge, refer detail, typical                                                                                                                             around base of plant and keep mulch 50mm                                                                  minimum 50mm clear of plant stem
                                                                                                                                                                  1/3 to 1/2 overall height of tree.
       above - mulch to back                                                                                                                                                                                                                                         from trunk base
                                                                                                             Fix edging with 3x F14 hardwood
       of kerb, typical                                                                                      50mm x 25mm x 450mm stakes, with 2x                                                                                                                                                                                                                               Ameliorated site topsoil as specified, avoid
                                                                                                                                                                                                                                                                     100mm deep organic mulch as specified.
                                                                                                             galvanised nails to fix stakes to edging, typical                                                                                                                                                                                                                 compaction, typical
       Rootball                                                                                                                                                                                                                                                      Mound mulch at edge of plant pit to collect
                                                                                            1800




       Street tree,                                                                                                                                                                                                                                                  water to fall down edges of plant pit.
       refer detail below
                                                                                                                                                                                                                                                                     Turf as specified
                                                                                                                                                                                                                                                                                                                                                                               150mm deep cultivated subgrade, typical
                                                                                                             'Figure 8' hessian tree tie, typical
                                                                                                             Hardwood stakes (2), see section set parallel                                                                                                                                                                                                                     Slow release fertiliser as specified. Use
                                            KERB INVERT




                                                                                                             to road, typical                                                                                                                                                                                                                                                  phosphorus free tablets for Banksia,
                                                                                                                                                                                                                                                                     Tree pit to be excavated to nominal depth of
                                                                                                                                                                                                                                                                                                                                                                               Callistemon and Grevillea species.
                                                                                                                                                                                                                                                                     600mm. Backfill hole with 100% friable
                                                                                                                                                                  Slow release fertilizer
                                    ROAD




                                                                                                                                                                                                                                                                     ameliorated site topsoil firming progressively.
                                                                                                                                                                  as specified                                                                                       All excavated fill to be removed off site. Scarify
                                                                                                             2x hot dipped galvanised triple grip screw to fix                                                                                                                                                                                                                 Subgrade
                                                                                                             mitred timber edging together, typical                                                                                                                  all sides of plant pit, typical.

       NOTES:                                                                                                                                                                                                                                                        100mm deep uniform gravel layer. Provide
       Extent of tree pit excavation to be 1800mm x 1800mm in area, minimum (subject to footpath location). Remove all excavated fill off-site.                                                                                                                      clean connection to road drainage as advised
       Place tree, 1000mm from back of kerb, or between kerb and footpath as applicable.                                                                                                                                                                             on site by civil engineer.
       Garden areas to extend from back kerb to footpath, typ.
       Edging to extend to footpaths where applicable with street tree centrally located within garden (allowing for services setbacks), refer to                     4            Tree Planting - in Garden or Turf                                                                                            1:30          7           Tubestock Planting                                                          N.T.S.
       plans for path locations.
       Ensure crown of rootball level is set higher than adjacent finished ground levels to prevent excessive ponding around rootball.                               LD3           Typical Section                                                                                                                           LD3          Typical Section
       When footpath is adjacent to street tree install root barrier to footpath side of plant pit as per notes above.


                                                                    1800


                                                                                                             Full and even crown, typical
                                                                                                             2 - 50mm x 50mm x 2400mm F14 hardwood
                                                                                                             centrally pointed non-treated stakes (shown
                                                                                                             perpendicular to kerb for graphic clarity only)
       50mm wide hessian tree ties                                                                           to be driven vertically into ground outside of the
       wrapped loosely around trunk,                                                                         rootball and shall have a finished height lower
       then a figure 8 and secured to                                                                        than the tree's lower lateral limbs                  Plant pit 2x width of respective pot.                           2x pot Ø                         Shrub / groundcover / tufty
                                                                                                                                                                  Scarify all pit walls and bottom, typ.                                                           grass plant species per plan                                                                                                                                                                                                  600mm
       stake with galvanised nails or                                                                        Form shallow saucer shaped depression                                                                                 Pot Ø                                                                                                                                                                                                                                                         typical
       staples. Position tree tie between
                                                                                                             around base of plant and keep mulch 50mm
       1/3 to 1/2 overall height of tree.
                                                                                                             from trunk base                                      Backfill plant pit with specified                                                                100mm deep and settled organic
                                                                                                                                                                  topsoil, avoid compaction, typ.                                                                  mulch as specified, keep minimum
                                                                                                             100mm deep organic mulch as specified.
                                                                                                                                                                                                                                                                   50mm from plant stem. Form shallow
                                                                                                             Mound mulch at edge of plant pit to collect
                                                                                                                                                                                                                                                                   dish drain to base of plant, typ.                                                                                                                                                                                             Varies,
                                                                                                             water to fall down edges of plant pit.               Garden topsoil as specified,
                                                                                                                                                                  avoid compaction, typ.                                                                                                                                                                                                                                                                                                         refer
                                                                                                             Turf as specified                                                                                                                                                                                                                                                                                                                                                                   Plans
                                                                                                             Timber Edge Detail 1 - LD3
                                                                                                                                                                  100mm, typ.
                                                                                                                                                                                                                                                                   Slow release fertiliser as specified.
                          600




                                                                                                             Tree pit to be excavated to nominal depth of                                                                                                          Use phosphorus free tablets for
                                                                                                             600mm. Backfill hole with 100% friable               2x rootball depth, typ.
                                                                                                                                                                                                                                                                   Banksia, Callistemon and Grevillea
                                                                                                             ameliorated site topsoil firming progressively.                                                                                                       species.
                                                                                                             All excavated fill to be removed off site. Scarify
       Slow release fertilizer                                                                               all sides of plant pit, typical.                     150mm, typ.                                                                                      150mm deep cultivated
       as specified                                                                                                                                                                                                                                                subgrade, typ.
       150mm cultivated subgrade                                                                             100mm deep uniform gravel layer. Provide             Existing subgrade, typ.
       and pit walls                                                                                         clean connection to road drainage as advised
                                                                                                             on site by civil engineer.                                                                                                                                                                                                      Road                                                                             Back of kerb or hardstand              Turf Roll, typical


           2              Street Tree Planting - Timber Edges                                                                                        1:30             5          Potted Shrub, Groundcover Planting                                                                                                            8          Turfing
           LD3            Typical Section Detail                                                                                                                     LD3         Typical Section Detail                                                                                             N.T.S.                   LD3          Typical Plan Detail                                                                                                                                    N.T.S.



                                                                                                                                                                                            NOTES:
                                                                                                                                                                                            This plan is Copyrighted © by Bird Landscape Design (Brian Bird - AILA RLA #1736).
                                                                                                                                                                                                                                                                                             Landscape Operational Works Package                Project:                                                                                        BIRD LANDSCAPE DESIGN
                                                                                                                                                                                            Any reproduction or unauthorized use without written consent from                                Job No: 2391                                      Proposed Multi-unit Development                                                                  Landscape Architecture, Urban Design, Land Planning
                                                                                                                                                                                            Bird Landscape Design is strictly prohibited.                                                                                                      11C Church Street, Pomona, QLD                                                                   3 Vector Place, Little Mountain, QLD 4551 Australia
                                                                                                                                                                                            Do not scale from PDF plans.                                                                                                                                                                                                                        M: +614 7705 5222
                                                                                                                                                                                            All dimensions in millimetres unless noted otherwise.
                                                                                                                                                                                                                                                                                             LD4        Details                                                                                                                                 E: [email protected]
23.10.23        A         For Application                                                   BB         BB
                                                                                                                                                                                                                                                                                             Sheet Title                  Sheet 4 of 7          Client: Zaccale Pty Ltd                                                                         W: birdgolfdesign.com
DATE            ISSUE DESCRIPTION                                                           DRAWN CKD
Log in to download the original file

Approved Plans - RAL23 0021 & OPW23 0177.pdf · 101 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.