APPENDIX 1                                   Water Sensitive Design Code Assessment                           (Noosa Plan)

SPECIFIC OUTCOMES                                          PROBABLE SOLUTIONS                                        PROPOSED SOLUTIONS
Water reuse
01 Development uses a combination of detention and         51.1 Development complies with the water quality          S1.1 The site is located within the Mary River catchment
retention systems to capture run-off from areas on the     standards in Table 2 of the SEQ Regional Plan             and adjacent to Blackfellow Creek. Blackfellow Ck is a
                                                                                                                     defined as a lowland freshwater on Plan wa 1381. The
site;                                                      Implementation Guideline No. 7 for Water Sensitive
                                                                                                                     EPP (Water)2009       -

                                                                                                                                               Mary River environmental values and
AND                                                        Urban Design;
                                                                                                                     water quality objectives details that lowland freshwaters
                                                                                                                     have the following wao’s:
02Water storage devices must have sufficient               52.1 No solution provided
                                                                                                                     Turbidity < 50 ntu
capacity having regard to local rainfall pattern and the                                                             Suspended solids < 6 mg/L
catchment area of roof or other hard standing surface;                                                               Chlorphyll a < 5 ug/L
AND                                                                                                                  Total Nitrogen < 500 ug/L
                                                                                                                     Oxidised N > 60 ug/L
03Captured water is utilised for all non-potable uses      53.1 Captured water is plumbed to be available for all    Ammonia N < 20ug/L

on site;                                                   external uses including gardening, irrigation, ponds,     Organic N < 420 ug/L
                                                                                                                     Total phosphorus < 50 ug/L
                                                           filling swimming pools and outdoor cleaning, as well      Fitlerable reactive phosphorus < 20 ug/L
AND                                                        as all ground floor toilet cisterns and washing
                                                                                                                     DO 85%     -
                                                                                                                                    110 %saturation
                                                           machine cold taps;
                                                                                                                     pH 6.5 -8.0
                                                           AND
                                                                                                                     S2.1 and S3.1 & 3.2
                                                           53.2 Where the captured water is used for toilet          Rainwater tank volume to be 1 ,600kL with backup supply

                                                           flushing and/or laundry use, an automatic or manual       from on-site dams to ensure sufficient water supply for
                                                                                                                     chickens.
                                                           interchange device that allows alternate use of
                                                           captured water or the reticulated water supply is
                                                           installed to ensure that there is a continual supply of
                                                           water for sanitary flushing and laundry use.


04 On-site detention does not adversely impact on          54.1 No solution provided
water requirements downstream of the site where the                                                                  S4.1 The site is 38 hectares in area and the proposal will
water is required to sustain the ecology and hydrology                                                               not affect ru nott.
of downstream systems (environmental flows);
AND

                                                                                                                     S5.1 N/A
05Within the Shire Business Centre site, as shown          55.1 No solution provided


                                                                                                                                                                                     A
1209 Animal Husbandry   Top Forestry Rd, Ridgewood
                        -
                                                                                          swaMP
April 2013
Log in to download the original file

Response to Information Request - MCU12_0184.pdf · 122 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.