Town Planning Report (rec. 16.04.25) · MCU25/0042
adequate, reliable, water tank available
safely located and freely for firefighting
accessible water supply is purposes with an
provided for fire fighting onsite water volume
purposes, which is in of not less than
addition to day to day 5,000 litres; and
water supply. (b) a water supply outlet
pipe 50 millimetres in
diameter and fitted
with a standard fire
brigade fitting
connected to the
water supply (other
than where the water
supply is in a
swimming pool or
dam).
PO16 Development is designed AO16.1 Where the development The site is not within a flood
and sited to ensure risk to is located in the Flood hazard area - not applicable
people and property Hazard Area as shown
from flooding is avoided on Flood Hazard
or minimised. Overlay Map in Schedule
2,
the finished floor level of
habitable rooms is at lea
st 300 millimetres above
the Defined flood event
(DFE).
AO16.2 Where the DFE has not The site is not within a flood
been modelled for the hazard area - not applicable
area, the finished floor
level of habitable rooms
is at least 500 millimetres
above the highest record
ed flood.
PO18 Development is AO18.1 Development including Not applicable to this
sufficiently separated any sensitive land uses is application.
from major electricity at least:
infrastructure and (a) 50 metres from a
substations to minimise transmission substatio
the likelihood of nuisance n;
or complaint. (b) 10 metres from any
other substation; and
(c) 30 metres from a
transmission line
easement.
AO18.2 Habitable buildings are Not applicable to this
not located within an application.
easement for a
distribution line.
PO19 Development is located AO19.1 Noise emissions do not The building has been
and designed to avoid or exceed 5db(A) above designed to be sympathetic to
minimise noise nuisance background noise level neighbouring properties.
from the use of internal to a Suitable fencing and
infrastructure. habitable building measu landscaping will be installed
red in accordance with to provide for privacy and
AS1055. acoustic purposes.
PO20 Wherever practicable AO20.1 Where adjoining Not applicable to this
habitable buildings are substations or major application.
orientated to avoid direct electricity infrastructure,
overlooking of major habitable buildings are
electricity orientated so that the
P a g e | 18 TOWN PLANNING REPORT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Town Planning Report (rec. 16.04.25).pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.4 MB (small file)
- File type
No other editions are linked here.