Skip to the record
Noosa's #1 Council Tracker.

Council archive · source document

Town Planning Report (rec. 16.04.25) · MCU25/0042

of 40

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

       adequate, reliable,                         water tank available
       safely located and freely                   for firefighting
       accessible water supply is                  purposes with an
       provided for fire fighting                  onsite water volume
       purposes, which is in                       of not less than
       addition to day to day                      5,000 litres; and
       water supply.                          (b) a water supply outlet
                                                   pipe 50 millimetres in
                                                   diameter and fitted
                                                   with a standard fire
                                                   brigade fitting
                                                   connected to the
                                                   water supply (other
                                                   than where the water
                                                   supply is in a
                                                   swimming pool or
                                                   dam).
PO16   Development is designed       AO16.1   Where the development         The site is not within a flood
       and sited to ensure risk to            is located in the Flood       hazard area - not applicable
       people and property                    Hazard Area as shown
       from flooding is avoided               on Flood Hazard
       or minimised.                          Overlay Map in Schedule
                                              2,
                                              the finished floor level of
                                              habitable rooms is at lea
                                              st 300 millimetres above
                                              the Defined flood event
                                              (DFE).
                                     AO16.2   Where the DFE has not         The site is not within a flood
                                              been modelled for the         hazard area - not applicable
                                              area, the finished floor
                                              level of habitable rooms
                                              is at least 500 millimetres
                                              above the highest record
                                              ed flood.
PO18   Development is                AO18.1   Development including         Not applicable to this
       sufficiently separated                 any sensitive land uses is    application.
       from major electricity                 at least:
       infrastructure and                     (a) 50 metres from a
       substations to minimise                     transmission substatio
       the likelihood of nuisance                  n;
       or complaint.                          (b) 10 metres from any
                                                   other substation; and
                                              (c) 30 metres from a
                                                   transmission line
                                                   easement.
                                     AO18.2   Habitable buildings are       Not applicable to this
                                              not located within an         application.
                                              easement for a
                                              distribution line.
PO19   Development is located        AO19.1   Noise emissions do not        The building has been
       and designed to avoid or               exceed 5db(A) above           designed to be sympathetic to
       minimise noise nuisance                background noise level        neighbouring properties.
       from the use of                        internal to a                 Suitable fencing and
       infrastructure.                        habitable building measu      landscaping will be installed
                                              red in accordance with        to provide for privacy and
                                              AS1055.                       acoustic purposes.
PO20   Wherever practicable          AO20.1   Where adjoining               Not applicable to this
       habitable buildings are                substations or major          application.
       orientated to avoid direct             electricity infrastructure,
       overlooking of major                   habitable buildings are
       electricity                            orientated so that the




  P a g e | 18                                                TOWN PLANNING REPORT

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Town Planning Report (rec. 16.04.25).pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.