Council archive · source document
Appendix A - Proposal Plans · MCU17/0004
Attached to the e-mail REC17/0002, MCU17/0004 & OPW17/0005 Boundary Realignment, Material Change of Use (2 x duplexes) & Op Works - 46-48 Elizabeth St, Noosaville.
Plans and drawings: the text below has words only, no drawings.
ELIZABETH STREET
BM: NAIL IN KERB
RL: 1.600
43
1. 47
57
1. .40
1. .35
57
5
58 4
61
1.
51 1.5
1. 1.4
48
54
1.
1.
1.
PP
1
1
PP
59
1.
1.
55
54
56
50
54
1.
1.
1.
1.
1.
40
55
WM
1.
1.
WM
66
54
1.
03
1.
58
20.92 20.92
58
2.
1.
59
64
1.
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252
17.10 2
74
2 STOREY
1.
BRICK UNITS
35.46
GTP395
3
59
67
1.
1.
6.09 7 2
66
1.
77
742m²
1.
1.
SHED
2
35.46
630m²
SINGLE STOREY GTP156216
5
68
1.
TIMBER & FIBRO
18.36
DECK
IO
MH
LL: 1.53 CP
49
1.
IL: 0.52
50
47
65
1.
1.
1.
14.83 20.92
60
1.
SINGLE STOREY4 RP72986
2 STOREY
BLOCK & H'PLANK
6 GTP671
DECK
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
LEGEND 2. ALL DIMENSIONS IN. MILLIMETRES
seve 3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
“we DRAWINGS,
Xv 4, ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
~ EXISTING SURFACE SPOT LEVELS. DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5, THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
LOTS 2 & 3 ON RP 78252 E INDICATES OVERHEAD ELECTRICITY WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
Level Datum AHD SUPPLY LINE DIAGRAM.
Level Origin PM 56277, RL 1.635m FOOTPATHS AND DRIVEWAYS:
N INDICATES EXISTING SEWER LINE 1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY FINISHED
| | TT ——_INDICATES TELSTRA LINE. APPROX TP OONCRETE SURFACE TOLERANCE +5.0nm OVER 30
a .Umm .Um
ALIGNMENT, BUILDER TO CONFIRM 5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
EXACT LOCATION PRIOR TO WORKS 6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
Sw/EX INDICATES EXISTING STORMWATER 8, ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
/ DRAIN 9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
—THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE |S TO BE ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95% THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (|.E. SAND TO A
CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
BM: NAIL IN KERB ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
. (PLASTICITY INDEX LESS THAN 25%, LINEAR SHRINKAGE OF 15%). THE
4 —— 2 oO uel KERB Mo RL: 1.600 PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
E
os PR? e " ENGINEERS PRIOR 70 ITS REMOVAL TO ENSURE ITS COMPATABILITY.
E E E E — THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
& \ \’ AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
w w—4it— w <—w ivr w w CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%
pe R.P. BOUNDARY COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED 10 SCG
OR 30.92 ae Te > 20.92 @. CONSULTING ENGINEERS FOR APPROVAL.
: S : @ = FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS TO BE
\ IN STRICT ACCORDANCE WTH THE ASSOCIATED DETAILS AND
COMM SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
\ — BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
I ll
\ a ~ FIELD DENSITY OF 95%.
9 — ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
1 \ ! 2? ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
E
S pe
2 nS ?
R.P. BOUNDARY
8252
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
' \z PRIOR TO CONSTRUCTION COMMENCING.
17.10
7
EX. R.P. BOUNDARY
SHED | 2
630m? |
xEY EXISTING HCB's & NEW Sib DRAINAGE | | GTP156.
sRO 7 LINE TO BE PROTECTED AS PE.
rio SEWER/STORMWATER PROTECTION
~ |
< \
O |
lw 1
a |
DETAILS ON DRG 26281—-OWI.
PROPOSED
R.P. BOUNDARY
EX. SMH | 90
MH EX. SCP
TN MO » | | CP
IL: 0.52
R.P. BOUNDARY
C— — — _
Rs 14.83
EX. SCP
PD STOREY
SINGLE STORE | RP72986 | UbLocK & H'PLANK GTF
SITE PLAN — SITE SURVEY & EXISTING SERVICES
Scale 1: 200
ALL LINE MARKING TO BE IN ACCORDANCE
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
WITH THE QUEENSLAND MANUAL OF UNIFORM Revision | Description Date
TO BE PROTECTED IN ACCORDANCE WITH THE TRAFFIC CONTROL DEVICES & A.S 2890.1 Issue:
AUTHORITY RESPONSIBLE FOR THE SERVICE oARKING FACILITIES PART 1: OFF-STREET CAR FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
KEY The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
EX. SWPT EXISTING STORMWATER MANHOLE/PIT the written permission of SCG Consulting Engineers.
EX. SCP EXISTING SEWER CONNECTION POINT ot
RC. HW. REINFORCED CONCRETE HEADWALL ~ SCG prt at Project Ave:
EX. SMH EXISTING SEWER MANHOLE
EX. SWMH EXISTING STORMWATER MANHOLE \ srarsinngsocrgneesson
email:[email protected]
SWMH NEW 1050 STORMWATER MANHOLE web:www.scg-engineers.com
E.0.B. EXISTING EDGE OF BITUMEN
DEBUILD TA
K &C EXISTING KERB & CHANNEL Title:
N.SL. NATURAL SURFACE LEVEL
F.H. FIRE HYDRANT OPERATIONAL WORKS:
EP ELECTRICAL POWER POLE SITE SURVEY & SERVICES
www.dialbeforeyoudig.com.au KERB _EXISTING KERBING Project
Y Lots 2 & 3 RP/8252
< DIAL1100 Elizabeth St, NOOSAVILLE
BEFORE YOU DIG Date: Drawn
Nov 16 CSK
Checked: Drg No. Rev
0 1 2 3 4 5 ©
1:100 @ Al s
"13200 @ A3 “|S haréson 26281-OW1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
APPENDIX A - PROPOSAL PLANS.pdfRelated documentApplication case desk ↗
APPENDIX A - PROPOSAL PLANS.pdfRelated documentApplication case desk ↗
APPENDIX A - PROPOSAL PLANS.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.