ELIZABETH STREET
BM: NAIL IN KERB
RL: 1.600
43
1. 47
57
1. .40
1. .35
57
5
58 4
61
1.
51 1.5
1. 1.4
48
54
1.
1.
1.
PP
1
1
PP 9
5
1.
1.
55
54
56
50
54
1.
1.
1.
1.
1.
40
55
WM
1.
1.
WM
66
54
1.
03
1.
58
20.92 20.92
58
2.
1.
59
64
1.
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252
17.10
2
7 4 2 STOREY
1.
BRICK UNITS
35.46
GTP395
3
59
67
1.
1.
6.09 72
66
1.
77
742m²
1.
1.
SHED
2
35.46
630m²
SINGLE STOREY GTP156216
5
68
1.
TIMBER & FIBRO
18.36
DECK
IO
MH
LL: 1.53 CP
49
1.
IL: 0.52
50
47
65
1.
1.
1.
14.83 20.92
60
1.
SINGLE STOREY4 RP72986
2 STOREY
BLOCK & H'PLANK
6 GTP671
DECK
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
LOTS 2 & 3 ON RP 78252
Level Datum AHD
N Level Origin PM 56277, RL 1.635m
| RAINFALL
ROOF RUNOFF
V
FILTRATION PITS
Zz
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
DRIVEWAY
y
§
COUNCIL STORMWATER
SYSTEM
WATER CYCLE DIAGRAMATIC
INFILTRATION PITS
TREAT FIRST FLUSH RUNOFF FROM ROOF'S
—STORAGE AND ONGOING INFILTRATION
REDUCES DEVELOPED SITE RUNOFF
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN.
INSTALL TO NEW KERB
ADAPTORS AND MAKE
FOOTPATH GOOD.
ELIZABETH STREET
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN.
INSTALL TO NEW KERB
ADAPTORS AND MAKE
FOOTPATH GOOD.
FALL LANDSCAPED AREAS TO
FORMED FLOW PATHS TO DIVERT
TYPICAL.
r—— RUNOFF TO GRATED DRAINS AND
SW PITS. 1 in 100 MIN FALL.
BM: NAIL IN KERB
ADAPTORS AND MAKE
RL: 1.600 A FOOTPATH GOOD.
ait PR ll A=
- aa 7, - PR - Ps —
\ i & iy
WwW Ww vi Ww WwW vi iI
- * 0 er yrs GPS iio,
EBL |~ LS Tie
IL 1. ! : IL 1.70
AUSDRAIN ENVIROMODULE 2 | ST POOL OMODULE 2
INFILTRATION CELLS. REFER 1 x <_| (lx Ne eS REFER
DETAIL ON THIS SHEET. | x DETAIL ON THIS SHEET.
S| 7 proe-f
a | i f
8252 =| “— ===" 1500 wPve @ 1100
| /
= | UNIT 1 ___ al IDP.
S FFL 2.70 S / =
FALL. b UNIT 2 / | FALL. <
| of | Bos} 2s
| ZL + << r i / FFL 2.70 wo] BR
Swe @ qin) oo FALL. |“ / 3
i 150¢ uPVC @ 1:100 FALL. 3 } Sy |i [si 24
2 1245 —s =p <= p pp nit TP39
—-—- A eae GP2 rT -—-
6.09 ix =H J cw
TE? ~
or mH \ || al 3
no
SHED 2 ! > ? fk
ot Ps) | F
ZEALL “70 / .
REY Za ee >P15&.
LDP @ =
3RO © F o (266 FFL 2.70 ut (te
EXISTING HCB’s & NEW SW DRAINAGE oS a % | “Te
LINE TO BE PROTECTED AS PER = = “op | a
SEWER/STORMWATER PROTECTION < tH r ; _
DETAILS ON DRG 26281-OW1. O _ swf GP2 x sw cpp a | f8 26
Lu SL 245 DP = iL 2.00
—a EX. SMH 10 eel 2.68 =|
MHC’) EX. SCP POOL | P00
LL: 1.53 we SG : — P
0.52 | ed RR
& 14.83 swe RP. BOUNDARY Sup. 92
EX. SCP . ||
A | P STOREY 6 GTE MIN FALL. TYPICAL.
SINGLE STORE RP72986 ! -BLOCK & H'PLANK
SITE PLAN — STORMWATER MANAGEMENT
Scale 1: 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
THIS DRAWING IS TO BE READ IN CONJUNCTION
WITH THE STORMWATER MANAGEMENT REPORT BY
TO BE PROTECTED IN ACCORDANCE WITH THE SCG CONSULTING ENGINEERS (No. 25231(SWM)
AUTHORITY RESPONSIBLE FOR THE SERVICE
ALL PIPES TO BE LAID AT 1 IN 100 MIN.
UNLESS NOTED
AUSDRAIN ENVIROMODULE 2
INFILTRATION CELLS ? IN LINE
STACKED ? HIGH, WRAPPED IN
GEOFABRIC
1.0.S
STORMWATER
INFLOW FROM
ROOF ONLY
PROVIDE DROPS AT EACH END OF
THE PIT FROM THE MAIN THROUGH
DRAIN TO THE SLOTTED PIPE IN
THE BASE
ALL PIPE PENETRATIONS THROUGH THE
GEOFABRIC TO BE FITTED WITH STAINLESS STEEL
PIPE CLAMPS, GEOFABRIC TO BE LAPPED AT
JOINS WITH A ROOT INHIBITOR PROVIDED ALONG
THE JOIN LINES
2/125x75x4.0 RHS (GALV.)
LAID AT 1 in 100 MIN.
INSTALL TO NEW KERB
LEGEND
CONSTRUCTION NOTES
GENERAL:
INDICATES EXISTING SURFACE
4g.00 CONTOUR AND LEVEL TO AHD.
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
@ ARCHITECTURAL DRAWINGS.
Ne EXISTING SURFACE SPOT LEVELS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED 10 THE ENGINEER
IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
INDICATES DIRECTION OF FALL
FALL.
"> TO FINISHED SPOON DRAINS.
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE
THAT ALL NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED
CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
INDICATES PROPOSED FINISHED
SURFACE LEVELS
x [29.740
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY
FINISHED TREATMENTS, EG. STAMPING
GD-150
(TTT)
150(W) GRATED DRAIN WITH
HEAVY DUTY GRATE.
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB
DEPTH.
GP1 7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY
450Sq FIELD INLET, PRE-CAST
CONCRETE WITH RAISED GRATE FOR
LANDSCAPED AREA DRAINAGE.
2ND MESH WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE
EDGE OF CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED
GP2 PRIOR TO WORK COMMENCING
300Sq FIELD INLET, PRE—CAST
CONCRETE WITH RAISED GRATE FOR
LANDSCAPED AREA DRAINAGE.
eB
HYDRAULICS
1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY. REFER TO
ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIXTURES.
¢P3 2. ALL SANITARY HYDRAULICS AND WATER RETICULATION WITHIN: THE
450Sq PIPE JUNCTION BOX WITH
BOLTED LID, PRE-CAST
CONCRETE.
ALLOTMENT BOUNDARY TO BE IN ACCORDANCE WITH AS3500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AUTHORITIES
HAVING JURISDICTION, AFTER OBTAINING ALL NECESSARY PERMITS AND
APPROVALS.
4. THE CONTRACTOR IS TO CONFIRM THE POSITION OF ALL EXISTING
SERVICES AS INDICATED ON THESE AND ASSOCIATED PLANS PRIOR 10
INDICATES PROPOSED STORMWATER
DRAIN EXISTING MIN 1 in 100
GRADE U.N.O.
Sw
DP DENOTES APPROXIMATE DOWNPIPE
LOCATIONS TO BE CONFIRMED BY
THE COMMENCING OF WORK.
5. STORMWATER DRAINAGE PIPES SHALL BE CLASS SH UPVC OR CLASS
2 R.C.P RUBBER RING JOINTED PIPE AS NOTED LAID AT A MINIMUM
GRADE OF 1 IN 100 U.N.O. JOINS ARE TO BE CONSTRUCTED IN
ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS.
6. SEWERS 100MM DIAM. UPVC U.N.O. AND LAID AT A MINIMUM GRADE
OF 1 IN 60.
7. WATER SUPPLY PIPEWORK BELOW GROUND |S 10 BE ;
ARCHITECT AND HYDRAULIC
DESIGNER.
63MM DIAM. OR LESS - HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PIPEWORK TO BE
TYPE B COPPER.
9. WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS AND ALL
JOINS AND CONNECTIONS SHALL BE MADE ABOVE THE SLAB.
10. FIRE HYDRANTS ARE TO BE INSTALLED ARE TO BE INSTALLED IN
ACCORDANCE WITH AS2419.1. HOSE REELS ARE 70 BE INSTALLED IN
ACCORDANCE WITH AS2441.
11, CLEAN—OUTS, INSPECTION OPENINGS AND CLOSING CAPS SITUATED IN
VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO BE FITTED WITH EITHER
BRASS OR CAST-IRON COVERS.
12. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN APPROVED
CONCRETE PATH BOXES.
13. ALL WASTE PIPES AND WATER SERVICES PENETRATING SLABS TO BE
WRAPPED IN AN APPROVED FLEXIBLE JOINT JOINT WRAPPING.
14. THE TERM ’SERVICE’ REFERS TO THE MINIMUM INTERNAL PIPE
DIAMETER UNLESS NOTED OTHERWISE.
FALL LANDSCAPED AREAS TO
FORMED FLOW PATHS TO DIVERT
RUNOFF TO SW PITS. 1 in 100
PROVIDE INSPECTION OPENINGS
(|.0.S) FROM SLOTTED PIPE IN
BASE FOR FLUSH OUT
1.0.S
STORMWATER
OUTFLOW
THESE PITS CAN ONLY BE USED
FOR ROOF RUNOFF, ALL
DOWNPIPES TO BE FITTED WITH
LEAF AND DEBRIS GUARDS
PROVIDE SLOTTED PIPE
THROUGH BOTTOM OF
CELLS
AUSDRAIN INFILTRATION SOAKER PIT DETAIL
fann—1__?——)_'m1:100 © Al
1:200 @ A3
KEY
EX. SWPT EXISTING STORMWATER MANHOLE /PIT
EX. SCP EXISTING SEWER CONNECTION POINT
RC. HW. — REINFORCED CONCRETE HEADWALL
EX. SMH — EXISTING SEWER MANHOLE
EX. SWMH EXISTING STORMWATER MANHOLE
SWMH NEW 1050 STORMWATER MANHOLE
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
N.S.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
KERB EXISTING KERBING
Revision Description Date
Issue:
FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
‘ABN 40 098 481 899
C) St
DEBUILD TA
Title:
OPERATIONAL WORKS:
STORMWATER MANAGEMENT
Project
Lots 2 & 3 RP/8252
Elizabeth St, NOOSAVILLE
Date: Drawn
Nov 16 CSK
Drg No. Rev
| ee d 26281-SW1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
APPENDIX A - PROPOSAL PLANS.pdfRelated documentApplication case desk ↗
APPENDIX A - PROPOSAL PLANS.pdfRelated documentApplication case desk ↗
APPENDIX A - PROPOSAL PLANS.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.