RESIDENTIAL USES CODE
Table 14-24 — For All Residential Uses

Specific Outcomes                     Probable solutions                   Proposal
14.46 Effects of use
Electricity          supply           S1.1 No solution provided.           Complies
infrastructure                                                             The proposed development for
O1 The development does not                                                a Multiple Housing – Type 2
adversely impact on existing or                                            Duplex and will not adversely
future      electricity  supply                                            impact on existing or future
infrastructure.                                                            electricity supply.

AND

O2 All uses and works maintain        S2.1    Development for uses         Not Applicable
an adequate safe distance from        adjacent to or within 50m of an      The development is not adjacent
electrical infrastructure including   existing electricity substation      to or within 50m of an existing
substations,              overhead    incorporates noise attenuation       electricity substation.
powerlines, power poles and           measures to mitigate noise
transformers.                         impacts;
                                      AND

                                      S2.2 Buildings and structures        Complies
                                      (including swimming pools,           No buildings or pools will be
                                      sheds,      tennis     courts   or   constructed under overhead
                                      outbuildings)         are      not   electricity    lines  or within
                                      constructed under overhead           electricity easements.
                                      electricity transmission lines, or
                                      within electricity easements;
                                      AND

                                      S2.3 A minimum separation            Complies
                                      distance is maintained from the      Minimum separation distances
                                      electricity transmission line to     are achieved.
                                      the     closest     boundary   of
                                      habitable buildings and child
                                      activity areas, as follows—
                                      a) 20m for transmission lines up
                                      to 132kV;
                                      b) 30m for transmission lines
                                      between 133kV and 275kV; and
                                      c) 40m for transmission lines
                                      greater than 275kV.
Hot Water Systems                     S3.1 All hot water systems           Complies
O3 Hot water systems       are        installed are—                       An appropriate hot          water
installed and operated to             a) solar systems; or                 system will be installed.
support the efficient use of          b) electric heat pump systems;
natural resources and minimise        or
consequent pollution such as          c) natural gas or LPG systems; or
greenhouse gas emissions.             d) any combination of a), b) or
                                      c).
Water        supply     and           S4.1 & S5.1 For a Class 1            Not Applicable
conservation                          building other than a Detached       The site is included within a
O4 On-site water storage is           house or Multiple Housing            reticulated water area.
designed and operated to              Type 1, outside a reticulated
support the efficient use of          water service area, a
water;                                rainwater tank is to be installed

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

15385_Town Planning Report_230216.pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.