Council archive · source document
109 Gympie Terrace Noosaville APPLICATION · MCU16/0103
Attached to the e-mail MCU16/0103 & OPW16/0199 Development Application - 109 Gympie Terrace Noosaville.
Issue:
DEBUILD T/A
SCG
ABN 40 098 481 899
Title:
Project
Date: Scale: Drawn:
Drg No.
[OCR of page images]
DRAWING SIZE - Al
EX. SMH
11.000
TAPER
150¢ PIPE INLET PLACE AT
LOW POINTS ALONG
NEIGHBOURING BLOCK
TIMBER. SLEEP! H).
MBER SLEEPER WALL 700(H) & &
Lk
|
I} |
I} |
o l) |
POQL CPt
& | | we
| | |
| | z |
|| J = |
= si PROPOSED 4 REFER Drg C2 FOR af
5 = — DRIVE WAY DETAILS. & Ff
= = SI DUPLEX cH
oa =| x. " SH !
| | | Sd
WwW
| | ~
| | |
ata ||| po Pt
S I
| Ss [4
S| A |
= Ls ’ \
PB er | C we ve wr
a oe AL, ag Oo — ly
SW SW t SW SW SW SW. A
& EEE ETE EEE TEE we TG | dy
@O RW-01 @ x
$ &
Ae
SITE PLAN — STORMWATER DRAINAGE
Scale 1: 100
NOTE:
IF NEIGHBOURING SITES ARE
DEVELOPED THEN SIDE ENTRY
PITS ARE NO LONGER REQUIRED.
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
1/N12 TOP
GROUND LEVEL
190 BLOCK - CORE
FILLED N12-400 V & H. ———P
— LAP BARS SOOMM.
PROVIDE FULL HT.
MOVEMENT JOINTS AT
8.0M CTRS.
ALL CORES CLEARED <=
BEFORE POUR VIA
CLEAN-OUT BLOCKS. N P
GROUND LEVEL
O wg 200MM FREE DRAINING
450
FOOTING BEAM
\ XO
BACKFILL WITH AGI PIPE
TO OUTLET.
150 THK HEEL SL82
MESH TOP 40 COVER.
H B =
1200 | 800
800 | 600
500 | 200 3 0 0 B
SLIITM TOP & BOTTOM
R6 LIGS AT 900 CTRS
(RW-01) ~ RETAINING WALL
TYPICAL SECTION
NEWIBLOCK WALL
NEW FOOTING
(ZZ
350@ CONCRETE PIER
FOUNDED 300 BELOW K&D
SEWER HCB INVERT ND
|.
/ EXISTING HCB
8
FP
1000 Min. | 1000 Min.
BETWEEN TOP OF UNDERPINS AND
UNDERSIDE OF EXISTING FOOTING
> te DRY PACK MORTAR
rx
FP
(— FOOTING/SEWER CRITICAL DEPTH
3508 CONCRETE PIER
FOUNDED 300 BELOW
SEWER INVERT LEVEL
(7 SECTION
CONNECT SW PIPES TO
ADAPTORS
~
KERB
oa
GYMPIE TERRACE
aS
7
CONNECT SW PIPES TO
we
ADAPTORS
KERB VIA APPROVED KERB
KERB VIA APPROVED KERB
EX. SWPT
RC. HW.
EX. SMH
E.0.B.
K&C
NS.L.
TP
EP.
KERB
FALL
CPI
RW-01
BLOCK RETAINING WALL
AS SPECIFIED.
a
EXIST
FILLED ALLOTMENT GL
tm
ae
FILLED ALLOTMENT
EXISTING STORMWATER PIT
REINFORCED CONCRETE HEADWALL
EXISTING SEWER MANHOLE
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL
FIRE HYDRANT
TELSTRA PIT
ELECTRICAL POWER POLE
EXISTING KERBING
LEGEND
INDICATES EXISTING SURFACE
CONTOUR AND LEVEL TO AHD.
INDICATES DIRECTION OF FALL
OR DOWN AS INDICATED.
450Sq GRATED FIELD INLETS,
PRE-CAST CONCRETE. HEAVY DUTY
GRATE WHERE IN DRIVEWAY
INDICATES PROPOSED STORMWATER
DRAIN EXISTING MIN 1 in 100
GRADE U.N.O.
INDICATES EXISTING SEWER LINE
150¢ PIPE WITH GRATE OVER,
PLACE AT LOW POINTS ALONG
NEIGHBOURING BLOCK
TYPE 1 RETAINING WALL REFER
DETAILS
g
3
at ——BLOCK RETAINING
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
6. THE BUILDER MUST PROTECT ALL EXISTING NEIGHBOURING
STRUCTURES/BUILDINGS THROUGHOUT THE WORKS, PARTICULARLY DURING
EARTHWORKS. REFERENCE SHOULD BE MADE TO OUR CRITICAL DEPTH LINE
DIAGRAM OR SEEK GUIDANCE DIRECTLY FROM THIS OFFICE
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR 10
WORK COMMENCING
FILLING NOTES:
THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE PROOF ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95% THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7 BLOWS
PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER FOR A DEPTH
OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF COMPACTION TEST RESULTS
SHALL BE PRESENTED TO SCG CONSULTING ENGINEERS FOR APPROVAL.
— UPON THE WRITTEN APPROVAL OF THE SUBGRADE PREPERATIONS BY SCG
CONSULTING ENGINEERS THE ALLOTMENT IS TO BE FILLED TO THE SPECIFIED
LEVELS.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (LE. SAND TO A CLAYEY
SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY ORGANIC MATERIAL
AND HAVE A CLAY CONTENT OF LESS THAN 12% (PLASTICITY INDEX LESS
THAN 25%, LINEAR SHRINKAGE OF 15%). THE PROPOSED MATERIAL |S TO BE
INSPECTED BY SCG CONSULTING ENGINEERS PRIOR TO ITS REMOVAL TO
ENSURE ITS COMPATABILITY.
— THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1 CERTIFICATION
WITH A MINIMUM RELATIVE FIELD DENSITY OF 95% COPIES OF COMPACTION
TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING ENGINEERS FOR
APPROVAL.
— FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES |S TO BE IN
STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL BE
BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN ACCORDANCE
WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
— ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE PREPARATION
SHALL BE REMOVED AND REPLACED WITH THE APPROVED FILL MATERIAL
COMPACTED IN ACCORDANCE WITH AS2870-1996 10 ACHIEVE A MINIMUM
RELATIVE FIELD DENSITY OF 95%.
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED PRIOR
TO CONSTRUCTION COMMENCING.
PAVEMENT NOTES:
1. PRIOR TO PLACEMENT OF PAVEMENT MATERIAL THE SUBGRADE IS TO BE
STRIPPED TO LEVEL. ANY ORGANIC MATTER OR DEBRIS IS TO BE REMOVED
AND REPLACED WITH APPROVED COMPACTED MATERIAL. THE SUBGRADE
SHALL BE PROOF ROLLED TO A MINIMUM OF 98% DRY DENSITY AS
DETERMINED BY COMPACTION TESTING IN ACCORDANCE WITH AS1289
2. PAVEMENT MATERIALS SHALL COMPLY WITH THE FOLLOWING MAIN ROADS
DEPARTMENT SPECIFICATION MRS11.05:
— BASE COURSE TO CONSIST OF AGGREGATE TYPE 2.3, GRADING B OR C
3. PAVEMENT MATERIAL SHALL BE EXTENDED A MINIMUM OF 150MM BEYOND
THE EDGE OF DRIVE AND SHALL BE A MINIMUM OF 100MM THICK U.N.O.
4. BASE AND SUB-BASE COURSES ARE 10 BE COMPACTED IN LAYERS NOT
EXCEEDING 150mm IN THICKNESS TO ACHIEVE 95% DRY DENSITY OR GREATER
WITH ONE TEST PER 200mm THICKNESS OF EACH LAYER.
5. ALL COMPACTION TESTING RESULTS TO BE PRESENTED TO THE ENGINEER
FOR APPROVAL PRIOR TO PROCEEDING TO THE NEXT STAGE OF
CONSTRUCTION.
Checked:
RPEQ 5835
S Richardson
1° ~~ 4:250 @ AI
1:500 @ A3
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated drawings are
copyright and are not to be used or reproduced without the written permission of
SCG Consulting Engineers.
AMEND DATE DESCRIPTION APPR.
AMENDMENTS
SSUFOR APPROVAL
- DEBUILD T/A
SCG consulting ENGINEERS
STRUCTURALeCIVILeGEOTECHNICAL
ABN 40 098 481 899
WALL.
1509 ADJOINING
DRAIN FROM
GRATE CONNECT BOTTOM LAYER TO HAVE
TO 1509 UPVC \ 1508 uPVC PIPE WITH
TRENCH GRATE BORED
La THRU.
NEIGHBOURING
ALLOTMENT
SWP_~ TYPICAL DETAIL
1506 PIPE WITH GRATE
OVER, PLACE AT LOW 1508 UPVC
POINTS ALONG 1 IN 100
NEIGHBOURING BLOCK GRADE i
SECTION X-X
1/11 PROJECT AVE, NOOSAVILLE QLD 4566
Ph (07) 5455 5604 __Fax (07) 5455 5696
Title:
STORMWATER DRAINAGE
Project
109 GYMPIE TERRACE
NOOSAVILLE
Date: Scale: Drawn:
July 16 AS NOTED
m0 26199-C3 i
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
109 Gympie Terrace Noosaville APPLICATION .pdfRelated documentApplication case desk ↗
109 Gympie Terrace Noosaville APPLICATION .pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.