Planning Report

of 32

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

      Specific Outcomes                      Probable solutions                             Proposal
O24      All building entries are       S24.1 The number of entrances           Not applicable
designed to be obvious and easily       and exits are limited and main          No change to the entrance/exit
identifiable sites to enable external   building entrances/exits are located    points of the existing shopping
areas to be monitored.                  at the front of the site, in view of    centre or supermarket is proposed.
                                        the street. Where this is not
                                        possible, due to site or existing
                                        building constraints, a well defined
                                        path     is    provided     to    the
                                        entrance/exit;
                                        AND
                                        S24.2      All  entrances/exits    to   Complies
                                        buildings, are well lit and signed,     Entrance/exit points are well lit and
                                        and signage includes hours of           signed.
                                        operation;
                                        AND
                                        S24.3 Entrances/exits are located       Complies
                                        to provide a direct link to driveways   Entrance/exit points are within close
                                        and carparking areas;                   proximity to car parking areas and
                                        AND                                     driveways.

                                        S24.4     Recessed doorways are         Complies
                                        avoided where the recess is of          Recessed     doorways     are    not
                                        sufficient size to conceal a person.    proposed.
                                        Where recessed doorways are
                                        unavoidable, measures are used to
                                        enhance
                                        safety, as follows—
                                          a) good lighting installed;
                                          b) strategically placed mirrors
                                          installed;
                                          c) angled approaches provided; or
                                          d) gates which restrict access
                                          provided.

O25    Uses are arranged within         S25.1      Windows       and main       Not applicable
buildings and on sites to enable        entrances are positioned to allow       The proposal is for an extension
external areas to be monitored.         for casual surveillance.                only, with no change to the existing
                                                                                building orientation and position.

O26     Communal open space,            S26.1    Communal open spaces,          Not applicable
including congregation and seating      including congregation and seating      The proposed extensions do not
areas, is located where it can be       areas are situated where they are in    include any communal open space
monitored.                              the line of sight of windows, doors     areas.
                                        and/or balconies of buildings, or
                                        can beseen from a street or other
                                        public space.

O27 Buildings and structures are        S27.1 Buildings or structures that      Complies
designed to minimise opportunities      are visible from a public street or     The extensions to the existing
for vandalism.                          laneway—                                supermarket are able use anti-
                                          a) avoid the use of solid fences      graffiti paint if required.
                                          and blank walls which attract
                                          graffiti.  Where     solid   blank
                                          surfaces      are     unavoidable,
                                          measures in the form of
                                          landscaping, creepers, murals,
                                          vandal resistant paint,
                                          etc are used;
                                          b) use toughened glass, security
                                          screens and other measures (but
                                          not including security shutters
                                          that obscure the view of
Log in to download the original file

Planning Report.pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.