06 of 10 GENERAL NOTES
lot 15 on RP89506
24 attunga heights, noosa heads qld 4567 2230
3670
1140
1945
elevation C
TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
elevation B
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
190
190
05 of 10 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
3040 4.HARDWOOD FRAMING TO BE MINIMUM STRESS
wc GRADE F14 & MINIMUM JOINT GROUP J2.
1850
2120
line of deck below
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
kit existing bath 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
3900
ACCORDANCE WITH AS 1684.2 2010
70
propose new kitchen UP 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
proposed deck extension
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL
UP
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
propose stacker doors
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
10690
AS NO RESPONSIBILITY WILL BE TAKEN AFTER
bed CONSTRUCTION HAS COMMENCED
3950
11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
8500
existing lounge living HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
dp
tiled deck 3660.1.2000
DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
bed REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
dp 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
190
190
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
820 REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
boundary line
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
existing 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
garage PRIVACY OPTIONS
(conc)
ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
elevation D
dp
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
06 of 10 INDICATIVE ONLY
existing line of garage at DOWNPIPES
1.78 drop from top of driveway dp ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
elevation A
2348 PANELIFT DOOR CONFIRMED AT TIME OF ROOFING CONSTRUCTION
existing upper floor
AND COMPLIANCE
05 of 10
existing 2700high block wall
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: PAUL COOPER BUILDER: PAUL COOPER MANDY'S DESIGN & DRAFTING SHEET: 4 of 10 DATE: ISSUE NO:
ALTERATIONS + ADDITIONS PH: 0438 343 151 QBCC NO: 1063563 PH: 0403 481 474 QBCC NO: 15117996 SCALE: 1:100 28 JUNE 2023 PC-2023-L
[email protected]
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH