GENERAL NOTES
lot 15 on RP89506
24 attunga heights, noosa heads qld 4567 Areas TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
Name Area THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
existing garage 61.26 m²
09 of 10 AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
existing ground floor 140.04 m² 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
190 70 70 70 190 proposed deck 47.66 m²
1700 3040 3670 1805 925 2620 MGP 10/MGP12
Elevation 3 - a existing upper floor 107.44 m² 4.HARDWOOD FRAMING TO BE MINIMUM STRESS
Grand total 356.40 m² GRADE F14 & MINIMUM JOINT GROUP J2.
4740 deck
Elevation 1 - a
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
07 of 10
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
190
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
exiting BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
fridge 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
1700
wc
1800
9. BUILDER AND TRADES ARE TO CONFIRM ALL
line of deck below
1200
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
2 2 SETOUT AND ORDERING OF MATERIALS
3900
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
existing bath AS NO RESPONSIBILITY WILL BE TAKEN AFTER
glass balustrading
CONSTRUCTION HAS COMMENCED
pantry
DN
2400
2400
11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
HER OWN WORK
8040
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
3660.1.2000
stacker doors
DOMESTIC SMOKE ALARMS
bed
7400
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
3950
1 1 WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
deck lounge 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
existing tiles
6600
AND INTERCOM SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
1700 REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
line of deck below
3140
bed S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
1700
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
190
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PROPOSED 2300H X 7400 LONG STACKER DOORS PRIVACY OPTIONS
existing
ELECTRICAL AND ENERGY EFFICIENCY
garage 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
DOWNPIPES
proposed upper floor
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
AND COMPLIANCE
Elevation 2 - a
09 of 10
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: PAUL COOPER BUILDER: PAUL COOPER MANDY'S DESIGN & DRAFTING SHEET: 8 of 10 DATE: ISSUE NO:
ALTERATIONS + ADDITIONS PH: 0438 343 151 QBCC NO: 1063563 PH: 0403 481 474 QBCC NO: 15117996 SCALE: 1:100 28 JUNE 2023 PC-2023-L
[email protected]
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH