Appendix A - Proposal Plans · EXE23/0035
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES
lot 15 on RP89506
24 attunga heights, noosa heads qld 4567 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
(height of posts to be 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
determined by builder) 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
2500 TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
3400 9. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
overall height to balustrade
new post AS NO RESPONSIBILITY WILL BE TAKEN AFTER
side boundary line
2530
CONSTRUCTION HAS COMMENCED
Elevation 2 - a 11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
6390
HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
3660.1.2000
DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
existing residence BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PRIVACY OPTIONS
proposed deck
proposed elevations cont'
ELECTRICAL AND ENERGY EFFICIENCY
(height of posts to be 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
determined by builder) AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
new post
DOWNPIPES
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
new balustrading CONFIRMED AT TIME OF ROOFING CONSTRUCTION
AND COMPLIANCE
Elevation 3 - a
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: PAUL COOPER BUILDER: PAUL COOPER MANDY'S DESIGN & DRAFTING SHEET: 9 of 10 DATE: ISSUE NO:
ALTERATIONS + ADDITIONS PH: 0438 343 151 QBCC NO: 1063563 PH: 0403 481 474 QBCC NO: 15117996 SCALE: 1:100 28 JUNE 2023 PC-2023-L
[email protected]
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH