GENERAL NOTES
lot 15 on RP89506
24 attunga heights, noosa heads qld 4567 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
existing 200x45 rafters 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
tiled decking system as 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
7.4 long stacker doors
per engineers design TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
beam as per engineers
2500
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
2100
design
balustrading 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
1200
as per aus
existing tiled deck
lounge 9. BUILDER AND TRADES ARE TO CONFIRM ALL
standards MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
SETOUT AND ORDERING OF MATERIALS
new shs 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
post beam 1700 AS NO RESPONSIBILITY WILL BE TAKEN AFTER
2530
+ footing as approx CONSTRUCTION HAS COMMENCED
per engineers 11. ALL TRADES ARE TO CONFORM WITH THE
design CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
work shop media HER OWN WORK
(height of posts to be 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
determined by builder) 3660.1.2000
existing posts + decking
DOMESTIC SMOKE ALARMS
Section 1 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
assumed roof pitch as per approx heights
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
approx 3080h WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
5.00° 8.00° REMOVED FROM DEVICE
approx 2500h 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
approx 2260h
BEDROOMS TO EXISTING RESIDENCES
proposed tiled S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
deck extension as
per engineers design GLAZING
2500
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
2100
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
existing tiled deck lounge existing bath TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
beam as per PRIVACY OPTIONS
engineers design
1700 ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
gym existing bth. DOWNPIPES
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
existing deck
posts + footings proposed posts + footings
as per engineers design
Section 2 AND COMPLIANCE
sections
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: PAUL COOPER BUILDER: PAUL COOPER MANDY'S DESIGN & DRAFTING SHEET:10 of 10 DATE: ISSUE NO:
ALTERATIONS + ADDITIONS PH: 0438 343 151 QBCC NO: 1063563 PH: 0403 481 474 QBCC NO: 15117996 SCALE: 1:100 28 JUNE 2023 PC-2023-L
[email protected]
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH