Attachment 5 - Document Referenced in Conditions - 2306-35006 SRA
Attached to the e-mail MCU23/0038 - SARA Referral Agency Reponse.
Provectus Algae Pty Ltd
ACN 625 465 572
5 Bartlett Rd
Noosaville, Queensland 4566
Traffic and Access Assessment
As required, PA will engage external contractors to manage traffic during non-standard
processes. There are no foreseen concerns regarding additional traffic or access issues to
the site during standard processes. The building site is located within an industrial zone.
Pest and Disease Management
Tanks are exclusively inoculated from cultures that have undergone rigorous identity and
purity speciation. Inoculation cultures are placed in quarantine until positive speciation
results are obtained in accordance with SOP-QUA-035 Incoming Materials Quarantine. This
robust testing includes morphological taxonomy and DNA barcoding. Any cultures showing
signs of impurity will be deemed unsuitable for production and will be disposed of following
approved decontamination and disposal protocols.
The closed system employed in the process significantly minimises the risk of pest and
disease contamination. Daily microscopic analysis is performed on the production culture to
ensure its integrity. The species used in production are not classified as pests or diseases,
nor are they known carriers of pests or disease-causing organisms. Consequently, there is
no anticipated unacceptable environmental or health risk associated with any potential
unintended release resulting from natural or man-made disasters.
The production area has a negative pressure differential of at least 5 pascals to restrict air
dispersion to the environment. In addition, a HVAC system shall be operational with hepa
filters to filter airborne microorganisms and particulate matter.
A tank cleaning procedure is established (SOP-PRO-010 Bioreactor Clean in Place
Procedure) to reduce the risk of tank bioburden.
An environmental monitoring procedure will be established within the production area to
allow for early detection of any microbial contamination issues and the implementation of
timely corrective actions.
Proceduralised entry requirements have been established to assist with mitigation of
pest/disease management. Furthermore, entry to the production area is regulated through a
controlled entry system and a dedicated airlock.
All wastewater will undergo dose chlorination prior to discharge to ensure that no viable
organisms are discharged to waste.
Nature, Accelerated
Email: [email protected] Website: www.provectusalgae.com
CONFIDENTIALITY NOTICE: This document is the property of Provectus Algae Pty Ltd and may not - in full or in part - be passed on, reproduced,
published or otherwise used without the express permission of Provectus Algae. Any disclosure, storage or reproduction of any part of this
document must be authorised in writing by Provectus Algae and then only in strict compliance with that authority.
PA-MAN-EMS Version 1 July 2023