Planning Report - 13 Eumundi-Noosa Road, Noosaville QLD 4566 - Dual Occupany

of 145

Page text read automatically using OCR, there may be inaccuracies

Flood Hazard Overlay Code
Table 8.2.6.3—Criteria for assessment

 Performance outcomes                                        Acceptable outcomes                            Response

 Floodplain protection, immunity and safety - for development areas

 PO1                                               AO1                                              Not applicable
 Development provides that for all flood events up The finished flood level is not less than the
                                                                                                    The subject land is for residential purposes and is
 to and including the DFE :                        minimum design levels specified in Table 8.2.6.4
                                                                                                    not included in Table 8.2.6.4.
          1. the safety of people on the site is
              protected; and
           2. the risk of damage to property on
              the site is avoided or minimised as
              far as practicable.

 PO2                                                         AO2                                             Complies with AO2
 All lots have sufficient area that is                       The minimum area above flood level (flood free
                                                                                                             The proposed development’s minimum area
 above the DFE flood level or where modelling is             area) for each lot, is in accordance with Table
                                                                                                             above flood level is in accordance with Table
 not available, the highest recorded flood level, to         8.2.6.5.
                                                                                                             8.2.6.5.
 safely and adequately accommodate the intended
 use.

 PO3                                           AO3                                              Complies with AO3
 For reconfiguring a lot or operational works, Development areas are not filled to reduce flood
                                                                                                Any filling or excavation undertaken will comply
 development is undertaken in a manner that risk.
                                                                                                with relevant regulations.
 ensures:
           1. natural hydrological systems are
              protected from erosion, scour or




Development Application: 13 Eumundi Noosa Road, Noosaville             Noosa Plan 2020: Amendment 1                                   Effective date: 25/09/2020

Log in to download the original (Planning Report - 13 Eumundi-Noosa Road, Noosaville QLD 4566 - Dual Occupany.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.