Council archive · source document
Response to RFI Sewer & Water Network Plans · OPW25/0057
Plans and drawings: the text below has words only, no drawings.
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO CONTACT THE RELEVANT
AUTHORITIES TO CONFIRM THE LOCATION OF
ALL EXISTING SERVICES PRIOR TO THE
COMMENCEMENT OF EXCAVATION
T
ex FH
LLAC
NE
DIA
DIAN
E LLA C
T
LAKE
MACD
900
ROAD 1
ONAL
D DR
FH FH FH FH
1 2 3
3163m² 7854m² 9148m²
FH
LEGEND
0m
ex FH R4
FIRE HYDRANT COVERAGE EXTENT
(40m RADIUS CENTRED ON HYDRANT)
PROPOSED ASPHALT ROAD
ex FH
PROPOSED CONCRETE FOOTPATH
100 PROPOSED CONCRETE DRIVEWAY & CARPARKING
1ha
BIORETENTION BASIN FILTER SURFACE
LANDSCAPE BUFFER
PROPOSED STORMWATER DRAINAGE
PROPOSED Ø150 PVC-O PN16 WATER MAIN
PROPOSED DN180 PE100 PN16 WATER MAIN
Shane Rynne
I,............................................. of COVEY ASSOCIATES Pty. Ltd. PROPOSED WATER VALVE
PROPOSED FIRE HYDRANT
18-03-2025
ON............................, CERTIFY that:
PROPOSED Ø150 UPVC SEWER MAIN
1. This design drawing has been assessed in accordance with
requirements of the SEQ Code and Unitywater Standards; EXISTING UNDERGROUND STORMWATER DRAINAGE
2. The construction of the works must only be undertaken in EXISTING WATER MAIN
accordance with this drawing; and
3. No design Amendments are permitted either before or EXISTING SITE BOUNDARY
during construction without the approval of Unitywater.
4. During construction, where required, Variation Notifications
must be submitted in accordance with the A&C Manual.
ACR/MAJ Check all dimensions before commencement of work.
Check Site boundary dimensions from the Title plans
2020-112
SIGNED: ......................................................... Check Building Boundary clearances by set out.
Notwithstanding the information supplied on this drawing,
SCALE 1:500 (A1) - 1:1000 (A3) the location, depth and extent of underground or overhead
services are to be confirmed and protected on site by the
contractor prior to commencement of works.
WM
Approved
Checked - CT Drawing title - Project - PROPOSED 1 INTO 3 Site - Project No. 233467 Sheet No. C480
Design - SK Drawn - SK
FIRE HYDRANT COVERAGE PLAN DEVELOPMENT 62 LAKE MACDONALD DRIVE, Digital Ref :
C480 FIRE HYDRANT
COVERAGE PLAN Issue : A
Scales - AS SHOWN COVEY ASSOCIATES PTY LTD 124 DUPORTH AVENUE Client -
NOOSA COUNCIL COOROY This Document is copyright and shall not be copied
A 16/05/2025 ORIGINAL ISSUE SK
ABN 59 137 305 992 PO BOX 16 without written approval, nor shall it be used except
Document Stage - APPROVAL (07) 5443 7777 MAROOCHYDORE QLD 4558 for the Development and the Site Specified.
Issue Date Description By [email protected]
c:\12dS\data\12dserver\233467_2957\dwg covey\OPW\uncontrolled\C480 FIRE HYDRANT COVERAGE PLAN.dwg Plot 1 July 2025 - 11:02 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to RFI Sewer & Water Network Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.