Original source · versioned page text
Appendix C - Code Assessment
Flood Hazard Overlay Code
AO4.3 – Not Applicable
Both Jirrima Crescent (southbound) and Lake Cooroibah Road
(southbound) remain impassable during a 1 AEP Event. The
AO4.3 proposed lots would offer a greater flood immunity than the
Where the existing roads servicing a development provide a existing service roads.
specific flood immunity (as determined by the Qld Transport
Road and Drainage Design Manual, Queensland Urban Drainage
Manual and the Australian Rainfall and Runoff Guide), all lots
have access to the flood free area identified in Table 8.2.6.5 that
matches the road immunity.
PO5 AO5 AO5 – Complies
For reconfiguring a lot or operational works, development does In the Flood Hazard Overlay, or in areas otherwise determined to The development will not cause any loss to flood storage
not directly, indirectly or cumulatively alter the flood be subject to the DFE or DSTE, development ensures: capacity or result in any changes to the hydrological regime.
characteristics external to the development site for all flooding
and inundation events up to and including a) there is no loss of on-site flood storage capacity;
the DFEor DSTE based on: b) all changes to level, depth, duration and velocity of
floodwaters are contained within the site for all flood events
up to and including the DFE based on current climate and
a) current climate conditions; and predicted impacts of climate change at 2100; and
b) incorporating an appropriate allowance for the predicted c) there is no acceleration or retardation of flows, or any
impacts of climate change. retardation in flood warning times, elsewhere on the
floodplain and to any overland flow paths; and
there is no increased stormwater ponding on sites upstream,
downstream or in the general vicinity of the site.
Resilient building design and form
PO6 AO6.1 AO6.1 – Not Applicable
Development ensures that building design and building form: Buildings are designed to integrate well with the street level and The site does not involve the development of new buildings or
a) accounts for potential flood risk; the levels of adjoining properties to facilitate pedestrian flows and structures.
b) is resilient to flood events; and visual and physical connectivity between the footpath and
maintains a functional and attractive street address appropriate
ground floors.
to the intended use.
AO6.2 AO6.2 – Not Applicable
Buildings incorporate appropriate screening to ensure that any
under-storey is not visible from the street, where such screening
does not impede flood water flows.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.