Skip to the record
For the highest quality transcripts.

Original source · versioned page text

4.0 Planning Report

Attached to the e-mail Amended DA Form 1 & Planning Report - MCU18-0062 & OPW18-0084.msg.

of 38

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

   column 1                               column 2
    Specific                 Probable solutions (if code assessable)
   Outcomes
                             b)    use toughened glass, security screens
                                   and other measures (but not including
                                   security shutters that obscure the view
                                   of shop fronts) are used in windows
                                   which are provided at ground level, to
                                   deter break and enters; and
                             c)    use hardy vandal proof materials
                                   and anti-graffiti paint are used in
O28 Lighting of                    the construction of buildings.
appropriate intensities                                                         Complies – Electrical
                             S28.1 Lighting of appropriate intensities is       contractors will install lighting
is provided to                provided which satisfies the requirements of
maximise safety.                                                                which meets Australian
                              Australian Standard AS1158: Public                Standard AS1158: Public
                              Lighting Code, unless otherwise specified in      Lighting Code, unless
                              this Code;                                        otherwise specified in this
                             AND                                                Code;
                             S28.2 External lighting of a graduated             Complies – The lighting design
                             intensity is provided which starts at a lower      achieves the solution.
                             level of brightness at the perimeter of the
                             site and rises to a higher level at the
                             entrance to buildings or at the centre of the
                             site;
                             AND
                                                                                Complies - Lighting spill has
                             S28.3 Lighting is directed onto the site and       been considered and will be
                             away from neighbouring properties;                 operated at acceptable levels
                             AND                                                and will not impact adjoining
                                                                                properties.
                             S28.4 Vandal-resistant lighting is used in
O29 Public toilets are       public and publicly accessible areas.              Complies - The lighting design
designed and constructed     S29.1 Public toilets are located in high           achieves the solution.
to—                          traffic areas;
a)    ensure the safety of
      all people using       AND                                                N/A
      them; and              S29.2 Features that may legitimise
b)    take advantage         loitering, such as seating or public
      of informal            telephones are not located within 20m of           N/A
      surveillance from      toilet entrances;
      adjoining uses
      and activities,        AND
                                                                                 N/A
      discouraging           S29.3 Entrances to public toilets are
      non-legitimate         visible from the street, footpath and other
      uses.                  activity areas on the site or adjoining
                             sites.                                             Complies

                             S30.1 Safe and convenient pathway access
O30 Premises have            is provided from the site to link to existing
accessibility to public      pathway networks that services public
transport.                   transport facilities;                         Complies
                             OR
                             S30.2 Direct pathway access is provided to
                             the public transport facility if the facility is
                             contained on site or within 50m from the
                             property boundary.




                                                                                 Building Suncoast Green            25
Log in to download the original file

4.0 Planning Report.pdf · 2.4 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.