2 David Low Way - Attachment 3 - Civil Engineering Assessment - Sheehy 10-8-17

Attached to the e-mail Reconfiguration of a Lot (1 lot into 6) - RAL17/0501.

of 74

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (16.6 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 30, section 1. The text section number identifies this passage in the reader.

Castaways — 2 David Low Way, Castaways Beach
Civil Works, including drainage, earthworks, erosion and sediment
control, waste management and services

 

Division 6 Residential Uses Code

 

Table 14-24 — For All Residential Uses

 

14.46 Effects of Use

 

 

Column 1 Specific
Outcomes

column 2 Probable
solutions (if code
assessable)

 

Electricity supply
infrastructure

O1 The development does
not adversely impact on
existing or future electricity
supply infrastructure; AND
O2 All uses and works
maintain an adequate safe
distance from electrical
infrastructure including
substations, overhead
powerlines, power poles
and transformers.

$1.1 No solution provided
$2.1 Development for uses
adjacent to or within 50m of
an existing electricity
substation incorporates
noise attenuation measures
to mitigate noise impacts;
AND

$2.2 Buildings and
structures (including
swimming pools, sheds,
tennis courts or
outbuildings) are not
constructed under overhead
electricity transmission
lines, or within electricity
easements;

AND

$2.3 A minimum separation
distance is maintained from
the electricity transmission
line to the closest boundary
of habitable buildings and
child activity areas, as
follows— a) 20m for
transmission lines up to
132kV; b) 30m for
transmission lines between
133kV and 275kV; and c)
40m for transmission lines
greater than 275kV.

The proposed development
is not within the prescribed
limits of any existing
electricity substation or
electrical transmission lines.
Electrical supply and
communications can be
provided to the proposed
lots.

 

Water supply and
conservation

O3 On-site water storage is
designed and operated to
support the efficient use of
water; AND O04 On-site
water storage is adequate

 

 

$3.1 & $4.1 For a Class 1
building*® other than a
Detached house , outside a
reticulated water service
area, a rainwater tank is to
be installed with the
following minimum storage

 

The development it
exclusively for detached
housing and is within a
reticulated water service
area.

 

1|Page

2/06/2017

 
Log in to download the original file

2 David Low Way - Attachment 3 - Civil Engineering Assessment - Sheehy 10-8-17.pdf · 16.6 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.