2 David Low Way - Attachment 3 - Civil Engineering Assessment - Sheehy 10-8-17

Attached to the e-mail Reconfiguration of a Lot (1 lot into 6) - RAL17/0501.

of 74

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (16.6 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 31, section 1. The text section number identifies this passage in the reader.

Castaways — 2 David Low Way, Castaways Beach
Civil Works, including drainage, earthworks, erosion and sediment
control, waste management and services

 

Column 1 Specific
Outcomes

column 2 Probable
solutions (if code
assessable)

 

for occupants every day use
and fire fighting purposes.

capacities— a) Where no
more than 3 bedrooms —
45,000 litres; or

b) Where more than 3
bedrooms — 60,000 litres;
AND c) There is to be on the
lot a dam, swimming pool or
water tank accessible for
use by the fire brigade that
contains at least 5,000 litres
of water

 

Sloping sites

016 On sloping sites,
buildings and structures are
designed to maximise the
use of the natural
topography and minimise
the need for cut and fill.

 

$16.1 Buildings and
structures on sloping sites—
a) Have a maximum
distance of 3m between the
ground and the lowest part
of the floor of the building
or the building incorporates
undercroft skirting or
screening (eg. timber
battens) to the full height of
any undercroft area higher
than 3m above ground level
at the perimeter of the
building;

b) are of split level design
that step down the slope or
have suspended floor
construction; c) limit the
amount of cut or fill to less
than 2m in depth relative to
natural ground level; and

d) do not result in the
spread of fill beyond the
footprint of the building and
associated batters

 

c) the cut and fill on the site
will be limited to no greater
than 2m relative to the
natural ground. The cut and
fill will be limited to that
required to enable servicing
and sewering of the
proposed lots. Benching of
the proposed lots is not
proposed.

 

 

Division 7 — Detached Housing Code

 

Table 14-28 — Detached houses, Ancillary dwelling units and Secondary dwellings

 

14.54 Siting & Effects of Development

 

Flooding, drainage and
earthworks’?

 

 

S4.1 Fill material placed
over services does not

 

No fill is proposed to be
placed over existing services

 

2|Page

2/06/2017

 
Log in to download the original file

2 David Low Way - Attachment 3 - Civil Engineering Assessment - Sheehy 10-8-17.pdf · 16.6 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.