Planning Report
Specific Outcomes Probable Solutions Compliance
of non-habitable areas; available-a minimum of 500mm
c) ensure carparking areas above the modelled flood level; and
can be adequately drained; c)for areas where flood modelling is
d) ensure drainage does not available, a minimum of 500mm
not adversely impact upon above the highest known flood level;
other premises; and AND
e) ensure filling or S14.2 Where Council infrastructure
514.2 Not Applicable
excavation does not is available-
The proposal will not require any
adversely im pact upon a) any drainage (including buildings artificial drainage.
other premises by- and yards) flows to that
i. causing ponding of infrastructure; and
water on the site or b) the infrastructure has the capacity
nearby land; to accept any additional loading;
AND
ii. increasing flooding, S14.3 Car parking and manoeuvring 514.3 Not Applicable
which adversely areas are constructed at a level that Car parking will not be required for this
affects the safety or permits the parking area to drain development because the use will be
unmanned. It is envisaged that service
use of any land from the site by gravity means,
vehicles can access the site from the
upstream and without the need for mechanical
car parking area to the east.
downstream; and pumping; or
S14.4 Basements for residential
514.4 Not Applicable
iii. adversely affecting uses have flood immunity above the
The proposed development is not for a
the flow of water in 0100 where alternative means to
residential use.
any overland flow mechanical pumping are used to
path. achieve such immunity; or
S14.5 Basements for non-residential
514.5 Not Applicable
uses have flood immunity above the
0100 that may be achieved by The proposed development will be
unmanned.
means of mechanical pumping
where the mechanical feature is
installed with adequate holding tanks
and an alternative Backup power
source.
Sloping sites S15.1 Buildings are of split level 015 Not Applicable
015 On sloping sites, design that step down the slope or The proposed development will be
buildings and structures are have a suspended floor construction; unmanned. The facility will not be multi-
designed to maximise the (See Figure 6.1 below) level and the site is not considered to
use of natural slope and AND have an excessive slope.
minimise the need for cut S15.2 Cut or fill is less than 2m in
and fill. depth;
AND
S15.3 The distance between the
ground and the lowest part of the
floor of the building does not exceed
3m.
Figure 6.1-Design for sloping site
(suspended floor)
.
~
/---,~1 ""
~
IiT~~’_:~ ~
~~~’~’:--t
~-
-/r
h 4hJ-
Roof form S16.1 With the exception of industrial 016 Not Applicable
016 Roof forms- buildings the main roof of the The main component of the proposed
a) contribute positively to building has a facility does not have a roof.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 of 2 , Planning report/Plans MCU12/0036Related documentApplication case desk ↗
About this file
- File size
- 28.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.