Original source · versioned page text
24-0578 Structural Issue A(3)(1)
BEARER NOTES:
1. Where a beam is to be supported by a SHS post, the post is
to have capping plates welded to each end, min 6mm plates
and fillet welds, UNO.
2. All steelwork to be hot dipped galvanised if used in exposed
conditions, otherwise cold galvanised or painted finish is adequate.
3. The number beside the fixing method indicates the number of
studs required under the bearer to support, ie (3) specifies the
bearer with 3 studs under. Refer connection details for tie down.
JOIST NOTES:
1. Where there is only a single joist span in a house, every
second joist shall be fixed at its ends with 1 Trip-L-Grip.
2. Joist hangers and Trip-L-Grips to be installed in strict
accordance with the manufacturer's specifications.
3. Use double joists where specified and under all loadbearing
walls, UNO.
4. Blocking at supports is to be provided to all joists in
accordance with AS 1684-2010 and the relevant manufacturer's
specifications.
5. Joists supporting load bearing walls to be tied-down to
supports with 1/Trip-L-Grip UNO.
dary
FLOOR FRAMING SCHEDULE:
un
Property Bo
MARK SIZE DESCRIPTION
BR1 200x50x3.0 Rectangular Hollow Section Bearer (cont., cantilever)
(Alloy & Temper - 6060/T5 or 6061/T6)
(Typical)
SJ1 200x50x3.0 Rectangular Hollow Section Structural Joist (cont. mult. spans) TR1
(Alloy & Temper - 6060/T5 or 6061/T6)
(Typical) (Typical)
DJ1 200x50x3.0 Rectangular Hollow Section Deck Joist (single span + cant.) BR1
C1
(Alloy & Temper - 6060/T5 or 6061/T6) Deck Joist* (cont. mult. spans)
SJ1
TR1 200x50x3.0 Rectangular Hollow Section Trimmer
(alloy & temper - 6060/T5 or 61006/T6 BR Steps by others
2
(Typical).
BR2
C1 315Ø Jetted Concrete Piles Concrete Pier
C1
Similar to Detail C. SJ1
NOTES: Typical.
BR1
DJ1
BR1
BR1
1
1. All floor joists to be at 450mm crs UNO.
BR
TR1
C1
C1
C1
C1
NOTE:
All fixings, connectors, plates and angles SJ1
to be Stainless Steel grade 316. Hidden line indicates Cantilevered framing must not
Similar to Detail A location of ST1. Typical. be fixed to revetment wall.
NOTE: Aluminum plate to end of
framing as specified by builder.
All Steel to be protected
as per AS/NZS 2312.1
NOTE:
All dissimilar metals to be
isolated to prevent corrosion
Property Boundary
Issue Made By Date Description PROPOSED NEW JETTY Scale : 1:20 NOTES:
A LL 21/11/24 Issue for construction
at LOT 91 (#25) SEAMOUNT QUAY, NOOSAVILLE
REVISION
Job No.: 24-0578 1. Do not scale drawings.
2. Scale is correct at A3.
BUILDER: PONTOON WORKS
Dwg No.: S03 3. Check and verify all dimensions
Designed By : L.LITTLE Drawn By : LL Date : 21/11/24 prior to commencement of work.
Certified By : B.R. CROMAR BEng (Civil) MIEAust CPEng RPEQ NER Date : 21/11/24 Ph: (07) 5444 5578 Email: [email protected] BEARER & JOISTS LAYOUT (Deck)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original