PLANNING & ENVIRONMENT COMMITTEE MEETING AGENDA 12 JUNE 2018
WASTE
Waste Disposal
12. The developer must provide waste storage and disposal facilities in accordance with
Planning Scheme Policy No. 9 “Waste Management Multi-Dwellings and Commercial
and Industrial Premises”. The facilities must include an external impervious area
correctly sized for all refuse and recycling containers and suitably screened from
public places and neighbouring properties. A bin wash area is required with a cold-
water tap, hose and drain outlet connected to sewer, via a bucket trap. The drain
outlet must be designed to prevent storm water entry to the sewerage system. This
can be achieved with a nib wall 50mm high and up to 700mm x 700mm wide (max
0.5m²), or alternatively the waste area can be roofed, or any other design approved
by Council.
13. Refuse containers must be provided in accordance with the requirements of the
Environmental Protection (Interim Waste) Regulation 1996 and (Waste Management)
Regulation 2000, for the storage and collection of refuse.
14. Public bins must be provided to reduce littering. All bins provided must be for refuse
and recycling and be decanted into the bulk bins by the site operators.
ENGINEERING
Site Access and Driveways
15. Sealed access driveways must be maintained from Main Street to all parking and
manoeuvring areas of the development.
Car Parking
16. A minimum of 5 car parking spaces must be provided and marked on the site and
made available and accessible at all times while the use is open for business. The
carparking must include in particular:
a. provision of vandal resistant public lighting with intensities to satisfy the
requirements of Australian Standard AS1158: Public Lighting Code
b. 1 disabled parking space/s within the total
c. dimensions, crossfalls and gradients in accordance with the relevant Australian
Standard (AS/NZS2890.1:2004 for staff and customers, AS/NZS2890.6:2009
for people with disabilities).
17. All car parking areas and access driveways must be maintained exclusively for
vehicle parking and manoeuvring and kept in a tidy and safe condition at all times.
Stormwater Drainage
18. Stormwater runoff from the development must be disposed of on-site without causing
scour or damage to the subject site or any adjoining property.
Earthworks and Retaining Walls
19. All earthworks and associated batters must be contained entirely within the subject
site unless written permission from the respective landowner(s) is provided to
Council. All earthworks must be undertaken in accordance with the provisions of
Australian Standard AS3798: Guidelines on Earthworks for Commercial and
Residential Developments.