Original source · versioned page text
response to information request
could be provided within the industrial 10m high building and not change the appearance from the street. Only two fixed metal louvre ventilation preferations at the rear of the building, the building appears similar to other large industrial 10m high buildings within the Cooroy Industrial area (see example at 4 Johnson Ct below). Figure. 2 10m high industrial buildings at 4 Johnson Ct, Cooroy Industrial area The design meets the relevant Specific Outcomes a and c-f of the Cooroy and Lake Macdonald Code, presenting a building height consistent with structures on surrounding premises which do not visually dominate the industrial streetscape. The design also meets the corresponding Overall Outcomes which seeks to accommodate uses and works that are designed and managed to contribute positively to the character of the locality without adverse impacts on the environment. 4. Provide amended proposal plans that demonstrate compliance with the Landscaping Code. In this regard, landscaped areas: a. Must be provided for a minimum of 15% of the site area; and b. Must be provided between the front boundary and the proposed shared area and PWD space. Although not providing for the full 15% landscaping requirement as sought by Probable Solution S1.1 of the Landscaping Code, the design increases the existing landscaping on the site from 90m2 to 150m2.The relevant Specific Outcomes seeks for new development to retain existing vegetation and enhance buffer areas around property boundaries; suit the relative size and nature of the development and its setting and conceal service areas. The proposed additional landscaping is located in areas around the permitter of the building and increase the size of the existing buffer areas in the corners of the site. This is also an opportunity to provide for more meaningful plantings within the existing landscaped areas. Considering the existing minimal landscaping and hardstand areas, the proposal reduces the amount of hardstand areas and allows for landscaping in front of carparking and service areas in accordance with the relevant Specific Outcomes. There is an existing security fencing is inward opening and hardstand areas are provided along the northeastern boundary. The proposal seeks to increase the landscaping along the frontage, while also providing for a more appropriate sliding security gate along the Jarrah St frontage. There is 300mm of area between the PWD parking unloading area and the new sliding gate, which does not allow for meaningful landscaping. The applicant is willing to accept conditions for more meaningful landscaping in front of the new sliding gate, so as to enhance buffer areas around property boundaries which are more suitable to the size and nature of the development and its industrial setting. Page 2 of 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (response to information request.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.