Council archive · source document
080630 FINAL TP Assessment Report.pdf [As Published] · 132008.1128
Very large file (22.5 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Protection. You need to be aware that there could be vegetation with high environmental values over the site. The application should be accompanied by a vegetation survey of the site which identifies the location and status of the vegetation and whether it warrants protection. Medium Bushfire Hazard Area of the Natural Hazards Overlay generally affects all of the part of lot 1 and the north western corner of Lot 6, whilst Low Potential Acid Sulfate Soils Area affects the western area of the part of Lot 1. Given the bushfire mapping over the site, your intention to engage a specialist consultant to address any issues / requirements (buffer, tracks etc) in relation to this matter is supported. Relevant Codes under The Noosa Plan The proposed development will be assessed against The Noosa Plan. It is noted that the most applicable codes include:- Eastern Beaches Locality Code Community Uses Code Engineering Works Codes Landscaping Code Biodiversity Overlay Code Natural Hazards Overlay Code Reconfiguring a Lot Code Application Fee: Reference is made to Council's website which contains a copy of the current fee schedule (07/08 financial year). In this regard go to Services and Facilities, A-Z Guides, F — Fees and Charges, Register of Regulatory Fees, under Table of Contents refer Land Use and Land Development fees. Land Use fees will include the fees for the Material Change of Use application. Whilst the fees for the Reconfiguring a Lot application are included under Land Development fees. It is recommended that prior to lodging the development application, you contact Council to confirm application fees. Notes: The following development parameters apply to the subject land:- Building Height - A maximum building height of 2 storeys and 8 metres above natural ground level applies to the subject site. From initial consideration of the section plans at the meeting it appears that the Independent Living Unit Apartment buildings non-complying with building height in storeys. These buildings could be interpreted as 3 storey, due to the basement extending greater than 1 metre above natural ground level. The proposal should be changed to comply; otherwise you should supply sufficient justification for a relaxation of the building height with the lodgement of the application. Population Density - The Noosa Plan does not identify a population density for the proposed use on the subject site. However you are advised that draft amendments have been prepared as part of Second Round Amendments to The Noosa Plan, which include maximum population density of 320 persons per hectare exclusively for the purposes of Residential Aged Care and 160 persons per hectare for any other form of Retirement & Special Needs Housing. Whilst these amendments are yet to be adopted by Council, due consideration would be given to these draft amendments when ~
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
080630 FINAL TP Assessment Report.pdf [As Published]Related documentApplication case desk ↗
About this file
- File size
- 22.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.