setback means the minimum distance from any /ot boundary to a building or structure,
excluding eaves, roof overhangs and awnings provided they encroach no more than 600mm
into the setback distance.

site cover means the proportion of a site covered by all buildings and structures shown as a
percentage. For enclosed spaces this includes the area within the outside wall and for
unenclosed spaces this includes the area measured along a line 600mm in from the perimeter
of the roof. Site cover includes garages and other roofed outbuildings, but does not include
landscape structures such as in-ground pools and decks. It is noted that the site cover stated
on the Proposal Plans includes the full roof area of the salas without making any allowance
for the permitted 600mm intrusion and hence they are overstated.

Please note, the Plan of Development notates that all dimensions and areas are approximate
only, and are subject to survey and Council approval, as such, the Proposal Plans have been
prepared in respect of the most recent Lot Caiculations Plan which accurately represents all
lot areas. Further, the Lot Calculation Plan identifies a 1-2m? increase in lot area to lots 84-88,
in comparison to the Plan of Development, which is considered negligible in the context of
calculating site cover.

2.1 Compliance with Elysium Master Plan (Key Development Requirements)

The approved Plan of Development for Elysium Noosa provides key development
requirements for a range of uses. The key development requirements table on the approved
Plan of Development indicates the general requirements for all Group Housing Development
precinct residential lots.

The provisions of the Key Development Requirements for Precincts are considered below:

Allotment 58

Key Requirements
Group Housing Development Precinct

Private Open Space
Entry Lots 901/902:

e No Dwellings or Structures other
than depicted in the approval
landscape plan are to be erected or
otherwise installed on these lots.

e Maintenance agreement to be
included in all bodies corporate to
ensure ongoing maintenance of
entrance features.

Group Housing Lots 94 & 99:
e Dwelling units within lot 94 & 99,
adjacent to the entry road, are to be
set back a minimum of 6 metres.

Compliant
No dwellings or Structures are proposed to be

erected on lots 901, 902, 94 & 99 as part of
this proposal.

 

General

General requirements for all group Housing
Development Precinct Residential Lots:

All buildings shall be screened where
practical to prevent the ingress of
mosquitoes and smaller biting midges.

Compliant
Screening requirements to be conditioned.

 

Site Cover
The maximum site cover for any lot shall not
exceed:

e 50% for ground floor; and

 

 

Compliant

The proposal is configured over one (1) storey
and comprises a total site cover of 46.7%,
less than the prescribed 50% site cover for

 

Page 3 of 26

 

Used in these records

About this file

File size
1.3 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Town Planning Report.pdf · 1.3 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.