Gross Floor Area
As detailed on the floor plans of Buildings 1, 2, 6 & 7 there are units which include annotation of
“drying court” in various locations for the purpose of a clothesline and air conditioning unit. These
appears are covered, and have an appearance of being fully enclosed and therefore contribute to
gross floor area. Revised plans have been requested to be amended the design to ensure the
development does not exceed a plot ratio of 0.5:1.
4. CONSULTATION
4.1. Referral Agencies
Not Applicable
4.2. Internal Council Referrals
The application was forwarded to the following internal Council officers for review and/or comment:
• Senior Development Engineer – as conditioned.
Traffic & Access
Access to the development is proposed via 6.3m wide left-in/left-out driveways onto Eumundi
Noosa Rd (Council Distributor) & Headland Drive (Council Collector). Both roads are in
accordance with PSP6 – Engineering Design Standards. PSP 6 Tables SC6.7.1 & SC6.7.2
recommend a desirable 3m/2m minimum) footpath width along Distributor Roads (Noosa
Eumundi Rd) and 2m desirable/1.2m minimum) footpath width along Collector Roads. The
existing footpath along both frontage is 2m. Amended plans have been provided showing the
extension of central medians on both Eumundi Noosa Rd and Headland Drive to ensure
traffic safety is maintained in accordance with the Driveway and Parking Code. The kerb and
channel is also to be replaced along Eumundi Noosa Road in accordance with the approved
OPW plans.
Single garage door widths for the proposed units have been provided demonstrating that
apron widths are in accordance with AS2890.1 Figure 5.4. Swept paths have also been
included demonstrating that a B99 vehicle can manoeuvre in and out of garages & internal
parking areas. There is 1 vehicle length of queue storage available at both accesses in
accordance with AS2890. The location of visitor parks along Headland Dr is therefore
accepted. Swept path manoeuvres have been provided showing that the waste collection
vehicle is able to perform a 3-point turn to enter and exit the development via the Eumundi
Noosa Rd access in a forward gear.
Standard conditions will be recommended for approval including that internal parking and
manoeuvring areas are in accordance with AS/NZS2890.
Utilities
Plans and Unitywater Service Advice Notice have been provided showing the proposed
sewer and water services easement and alignment will not affect Council Infrastructure. A
standard condition is recommended that the development obtain the relevant approvals in
relation to the public utility infrastructure.
Stormwater
Comments and conditions have been provided by Council’s external Stormwater Consultant
addressing the detailed stormwater design and management. The site generally slopes at
an average grade of 7% to the east through downstream properties and Council stormwater
infrastructure located along Starboard Avenue. A Stormwater Management Plan (SMP) has
been provided with the application material.
Stormwater Quantity – The applicant’s SMP certifies that the proposed development and
associated stormwater system mitigates the change in peak stormwater discharge and
ensures no worsening in accordance with the Water Quality and Drainage Code. The
Page 9 of 36
Document Set ID: 22528171
Version: 11, Version Date: 11/01/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - Planning MCU23 0094, OPW23 0113 & RAL23 0014 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.