Original source · versioned page text
51988.2770.02 APPLICATION FOR A MINOR CHANGE TO A TOWN PLANNING CONSENT FOR INDOOR ENTERTAINMENT AND EXTENSION OF AN INDOOR ENTERTAINMENT - 31 BUTLER STREET, TEWANTIN (Referred from Planning & Environment Committee dated 10 September 2024 - Item 5.1) · 2024-09-16 Attachment 2 to the General Committee Minutes (prev Att 4 to the Report) - 51988.2770.02 - Annotated Proposal Plans
Plans and drawings: the text below has words only, no drawings.
Original PDF page 3, section 1. The text section number identifies this passage in the reader.
W01 W02 W03 W04
KEY:
BLOCK, 140mm, PAINTED ABBREVIATIONS
BLOCK, 190mm, PAINTED BLOCK, 140mm, PAINTED NEW WALLS
BLOCK, 190mm, PAINTED ABBV DESCRIPTION
EXISTING WALLS B BASIN
NORTH BE BENCH (BY CLIENT)
DEMOLITION WORKS BL190 BLOCK, 190mm, FACE
FURRING CHANNEL, TOP HAT, 45mm BLP140 BLOCK, 140mm, PAINTED
FURRING CHANNEL, TOP HAT, 45mm
FIBRE CEMENT, 9mm ROOF LINE OVER
FIBRE CEMENT, 9mm
BLP190 BLOCK, 190mm, PAINTED
BLR BLOCK, RENDER-COAT, PAINT FINISH
COL-S COLUMN, STEEL
FIBRE CEMENT, 6mm, HARDIFLEX, FC CONCB-S CONCRETE, BROOMED, SEALED
W05 BLOCK, RENDER-COAT, PAINT FINISH W06 BLOCK, RENDER-COAT, PAINT FINISH W07 BATTEN JOINTS, PAINTED CONCI CONCRETE, INSITU
DP DOWNPIPE
STUD FRAME, 90mm NOMINAL FC9 FIBRE CEMENT, 9mm
BLOCK, 190mm, PAINTED BLOCK, 190mm, FACE
INSULATION BATTS FCR6H FIBRE CEMENT, 6mm, HARDIFLEX, FC BATTEN JOINTS,
PAINTED
FUR45 FURRING CHANNEL, TOP HAT, 45mm
FW FLOOR WASTE
FURRING CHANNEL, TOP HAT, 45mm GR GRAB RAIL, AS1428.1-2009 PWD COMPLIANT
WALL LEGEND FIBRE CEMENT, 9mm HB HAND BASIN
HR HANDRAIL
1 : 10 A B HW-P HOT WATER UNIT, ON PLINTH
04-00
05-00 05-00 IN1 INSULATION BATTS
SF90 STUD FRAME, 90mm NOMINAL
1 2 1 3 4 5 SH SHOWER
7590 7010 13590 1500 SK SINK
SS STAINLESS STEEL
600 190 4260 140 2210 190 7010 190 2810 140 10260 190 VYL VINYL
WC WATER CLOSET
2390 1810 2790 1610 3790 1610 4500 1200 4500 2000
WC-AC WATER CLOSET, AS1428.1-2009 PWD COMPLIANT
600 300 300 300 100 WC-AM WATER CLOSET, AS1428.1-2009 AMBULANT COMPLIANT
50
40 1020 40
TGSI
TGSI
RAMP RAMP
1020
2100 2100 UP 1:15 UP 1:15
W06 W05
190
190
100
0 0
DP DP DP
A DP
A
COL-S
W05 W05 W05
190
1200 190
50
190
990
W03
BE
990
WC D20
W01
700
FW SK
1960
1980
CLEANER FIRST AID
2310
VYL
W03
CONCB-S
D14
3200
990
D21
HR
WC
D13 STORE
1010
920
140
700 D09
3660
140
2110
W03 CONCB-S
4250
920
2110
HW-P
140
HR HB
390
900
1020
WC-AM D22 WC HB W04
D15
W05
W01
700 SS
THR
700
COL-S
1010
D12 FW D11
W05
HR 920 SK 920
SOCIAL ROOM
900 140
140
7590
CPT W03
1020
WC-AM D23 D16 WC 1 04-01
700
UNISEX TOILETS D10
2190
W02
CONCB-S 700
790
W05 W01 920
04-01 2
W03
1200
190
SH GR
1020
WC
HR
D17
3390
4760
CANTEEN
FW B 700 VYL
1610
WC-AC FW SS
GAME CONTROL/
W04
OFFICE
3410
B CPT 2100 MEETING ROOM
1020
W05
1410
3345
2960
D18 WC W04 CPT
1510
900
D08
PWD 700 SS
1510
VYL FW B
1200
FW COL-S
W03
1020
HB WC
800
B D19
190
190
790
D01 700 W06
W05 CPT W05
970
B W05 SECURITY SCREEN SS
B
190
190
2100 2100
W01 W02 2100
THR THR THR THR THR
HR
D02 0 D03 0 D04 D05 W03 D06 VERANDAH D07
3200
900 CONCB
1910 3010 2310 920 920 1510
HR
390 1010 1890 1910 2390 1610 390 3010 390 1610 1390 2310 1590 1010 390 1410 990 1010 1190 1510 790
2400
190 2310 140 4760 190 7010 190 4810 140 3310 140 4810 190
100 4200 4200 4200 4290 4200 4200 4200 100
HR HR
300 300
TGSI
100
1510
100
COL-S HR COL-S HR COL-S COL-S HR COL-S HR COL-S HR COL-S HR COL-S
DP DP
C C
300
DP DP
TGSI
TGSI
RAMP HR HR
1085
1200
UP 1:15
300 300
ATS ATS ATS ATS
300
UP
2400
HR
CONCI
TGSI
600
RAMP TGSI
1200
1020
900 3008 1200 3008 1200 3008 1200 3008 918
1:15 UP
1820
1750 5500 300 300
1 2 2 3 4 5
04-00
FLOOR PLAN
1 1 : 50
SCALE 1:50 @ A1
0 0.5 1 1.5 2 2.5 5m
REV. DESCRIPTION BY DATE DRAWING STATUS CONSULTANTS PROJECT DATE DRAWN BY
DEPT. OF TOURISM, INNOVATION AND SPORT - NOOSA DISTRICT NETBALL ASSOC. 12/04/24 IP
A PRELIMINARY See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.