7.5. Demonstrate how safe pedestrian access is proposed to each of the
Industrial Units, as the entrances to most of the proposed units is presently
proposed directly off the main circulation aisle. The present proposal raises
safety concerns and the applicant will need to provide a means of
separating pedestrian and vehicle safety to avoid any conflicts between the
two.
In this regard a 1.5m wide walkway, raised above the level of the circulating
road, may be required to the frontage of all of the Industrial Units to ensure
adequate separation between pedestrians and circulating traffic, and to
allow pedestrian friendly access to the proposed buildings.
Provision of landscaping elements to the frontages of the industrial units
should also be incorporated to soften the building façade, to create interest,
and to assist in reducing vehicle speeds on the circulating aisle.
7.6. To prevent vehicles from encroaching over proposed landscaped areas,
wheel stops will be necessary to most of the proposed car parking spaces
and these wheel stops should be shown on the amended proposal plan.
7.7. Staff car park spaces on a development of this scale, with 44 different
Units/tenancies, is inappropriate and will not function adequately. In
accordance with AS2890.1, staff car parks cannot be intermingled across
the development but instead need to be kept together if they are to work
properly. This however will be difficult to achieve in practice on this
development due to the size of the site. As such all spaces on site should
be sized as standard spaces 2.6m wide x 5.4m long, unless the space is
obstructed by an adjacent wall or fence, in which case the space will need
to be at least 300mm wider to allow access and room for car doors to open.
7.8. Provide at least 4-disabled carpark spaces (evenly distributed across the
development to maximises their usage) each with a minimum dimension of
3.2m wide x 5.4m long.
8. Demonstrate that the car park area (including all loading areas, manoeuvring
areas, and driveways) comply with Australian Standard AS2890.2 – Commercial
Vehicle Facilities. The issues addressed shall include:
8.1. Demonstrate that a 19m-semi trailer is capable of entering and leaving the
site in a forward gear with provision for such vehicle to be safely parked for
loading and/or unloading without restricting the operation of the industrial
facility. In this regard a designated semi trailer loading area needs to be
provided and this should be shown on the amended proposal plans along
with the swept path of this vehicle.
8.2. Demonstrate how it is intended to safely load and unload all trucks and
commercial vehicles, as there is concerned that these activities occurring in
a common area could other users of the site at risk. In this regard, it may
be necessary to provide additional loading bays to adequately serve the
site.
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0738 Request for Further Information - 010.2007.00000738.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 28 KB (small file)
- File type
No other editions are linked here.