Original source · versioned page text
RFI - Attachment F - Engineering Report
Very large file: it may take a few minutes
The original of this document is very large (15.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
2
Technical Papers
on a predictive determined to be identical with respect
probabilistic assessment to physical characteristics and therefore
of the sediment load the media should be considered
entrained within the equivalent with respect to expected
stormwater runoff solids removal performance.
from the site. Although
the cartridges were
Method
maintained on a yearly The Mitchell Community College
basis, a qualitative RCFS installation was evaluated over
assessment undertaken a 20-month period following system
at the time of the maintenance in November 2010.
cartridge exchange did Independent oversight of all aspects
not indicate that any of the project was provided by Ryan
bypassing of treatment Winston, MS, Extension Associate
occurred due to filter Engineer in the Department of Biological
occlusion. The yearly and Agricultural Engineering at North
maintenance frequency Carolina State University.
is unremarkable, given
Sample handling services (sample
the detention tank
retrieval, system reset and sample
upstream and the
RCFS’s passive surface submittal) were provided by Pace
cleaning mechanism, Analytical Services (Pace) and laboratory
which activates at work was conducted by Pace and Test
least once during America. Precipitation was measured with
Figure 2. Aerial view of the testing site. every runoff event a tipping bucket-type rain gauge. Influent
and deposits the and effluent water quality samples
The RCFS was designed as a capture- were collected by portable automated
waste on the floor of the cartridge bay.
and-treat system. The storage component samplers simultaneously collecting flow,
of the system (tank) is a 750mm diameter The RCFS system contained a total precipitation and water quality samples.
corrugated metal pipe (CMP) network of eight, 460mm high, media-filled Each automatic sampler was connected
designed to capture 75% of the calculated filter cartridges operating at a flow to the cellular network for remote
water quality volume (i.e. the runoff rate of 0.5L/s per cartridge. Each of communication and data access.
associated with a 25mm event). the filter cartridges was filled with an
activated alumina media. The media The influent sampler was equipped
The treatment component (StormFilter) used for this study was a granular perlite with an area velocity flow module with
was designed on a mass-loading basis coated with activated alumina; this was low profile sensor for flow analysis
required to meet the annual pollutant done to aid in the attenuation and/ and influent sample pacing. The effluent
loading requirements of the site with a or capture of nutrient pollutants by sampler was equipped with a bubbler
minimum estimated interval between cation exchange and adsorption. With flow module used in conjunction with
maintenance of one year. The estimation the exception of the surface coating, a weir for flow analysis and effluent
of the yearly maintenance was based coated and uncoated perlite media were sample pacing. Sample strainers and flow
water SEPTEMBER 2014
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.