3
Technical Papers
measurement equipment were secured efficiency as the average event mean Results and Discussion
to the invert of the influent and effluent concentration of pollutants over some Monitoring 13 storm events over
pipes using stainless steel spring rings. time period. a 20-month period resulted in the
Following a precipitation event, collection of cumulative rainfall
composite samples were submitted representing 704mm. Comparison of
for analysis according to accepted, The ER method assumes: 1) The weight the measured rainfall intensities is not
relevant EPA, ASTM (Suspended of all storm events is equal, regardless of wholly representative of that found in
Sediment Concentration) and SM254D the relative magnitude of the storm event; Australia due to varying climatic regions.
(TSS) methods. The field monitoring and 2) that if all storm events at the site The presence, however, of upstream
methods used for this study represent had been monitored, the average inlet storage attenuates flows from all storms
the current state-of-the-art practice and and outlet EMCs would be similar to those such that differences in rainfall intensities
are similar to those used by researchers that were monitored (URS/ EPA, 1999). ER are not a significant factor on treatment
in North Carolina to evaluate vegetated results for each parameter in the 13 events performance and pollutant wash-off. Full
stormwater treatment systems. sampled are summarised in Table 1. treatment flow through each RCFS is not
achieved until the water level inside the
To obtain a better understanding of Performance was also calculated using
chamber reaches a height of 460mm. At
RCFS performance with respect to solids, the Summation of Loads (SOL) efficiency
this water elevation a siphon is activated
the portion of SSC (Suspended Sediment calculation method. The SOL method
and the cartridge throughput of 0.5L/s
Concentration) particles smaller than defines the efficiency as a percentage
per cartridge is achieved, regardless of
500µm and 2000µm was also determined. based on the ratio of the summation of
the rainfall intensity.
all influent loads to the summation of all
For each of the 13 qualifying storm effluent loads. Non-parametric statistical methods
events sampled between November were used to evaluate correlations and
of 2010 and June of 2012: differences between non-transformed
1. The total rainfall was greater than
influent and effluent event mean
2.5mm for each event sampled; concentrations (EMCs), since influent
The SOL method assumes: 1)
and effluent EMCs were generally not
2. The minimum inter-event period was
Monitoring data accurately represents
from the same statistical distribution
greater than six hours for all storm the actual entire total loads in and out
due the complex nature and variability
events sampled; of the BMP for a period long enough
of stormwater monitoring. To test for
to overshadow any temporary storage
3. The minimum number of influent and
positive correlations between influent
or export of pollutants; and 2) Any
and effluent EMCs, the Spearman Rank
effluent aliquots collected per storm significant storm events that were not
Order Correlation test was used (USGS,
event was five; monitored had a ratio of inlet to effluent
1991). To evaluate the significance of
loads similar to the storms events that
4. Seven influent flow-weighted differences between influent and effluent
were monitored (URS/EPA, 1999). In an
composite samples covered ≥ 50% of EMCs, the Mann-Whitney Rank Sum Test
effort to eliminate the introduction of
the total storm flow, while six covered was used (USGS, 1991).
potential bias associated with observed
between 34% and 49%; effluent flow-
discrepancies between influent and For the Mann-Whitney Rank Sum
weighted composite samples covered
effluent measured volumes, it was Test the null hypothesis was that the
≥ 50% of the total storm flow for all
assumed that the influent volume was two samples were not drawn from
storm events sampled.
equal to the effluent volume. Measured populations with different medians. A
Performance was calculated using the effluent volume was used to calculate significant difference between influent
Efficiency Ratio (ER) efficiency calculation loads for both the influent and effluent and effluent EMCs was concluded
method. The ER method defines the sample locations. when P<0.05. Based on the use of the
Table 1. Summary of results.
Range of Median Mean Range of Median Mean Mean Removal Efficiency
no. of
Analyte Influent EMCs Influent Influent Effluent EMCs Effluent Effluent Efficiency Ratio
events
(mg/L) EMC (mg/L) EMC (mg/L) (mg/L) EMC (mg/L) EMC (mg/L) (Sum of Loads) (ER)
SSC < 2000
12 17.7 - 2080.0 53.4 231 1.9 - 7.2 3.4 3.9 98.3% 98.3%
micron
SSC < 500
12 9.0 - 393.0 28.6 66.1 1.7 - 10.0 2.8 4.4 93.7% 93.4%
micron
TP 11 0.065 - 0.9 0.14 0.223 0.025 - 0.058 0.025 0.031 87.1% 86.1%
PP 9 0.019 - 0.225 0.06 0.083 0.0 - 0.033 0.0 0.007 96.4% 91.3%
DP 9 0.025 - 0.850 0.054 0.155 0.025 - 0.160 0.025 0.04 67.3% 74.2%
TN 10 0.035 - 2.95 0.85 1.00 0.35 - 0.82 0.35 0.44 50.2% 55.9%
TKN 11 0.25 - 2.70 0.72 0.94 0.25 - 0.58 0.25 0.28 60.9% 70.2%
NH3-N 11 0.05 - 0.72 0.21 0.27 0.05 - 0.24 0.05 0.10 60.0% 62.8%
NOx 10 0.10 - 0.35 0.16 0.17 0.10 - 0.35 0.10 0.16 11.2% 9.8%
SEPTEMBER 2014 water
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.