4. Minimum setback distances (from Queensland Plumbing and Waster Code March 2019)
VERTICAL SEPARATION Advanced
Unsaturated soil depth to a permanent water table or 0.3m
impermeable rock layer
HORIZONTAL SEPARATION - Distance from the edge
of the bed/trench to the nearest point of the feature
Top of bank of permanent or intermittent water course or lake, 10m
bay or estuary; or
Top water level of a surface water source used for agriculture,
aquaculture or stock purposes or;
Bore or a dam
Property boundaries, pedestrian paths, footings of buildings, 2m
recreation areas, retaining wall footings - up slope or level with
the land application area
Property boundaries, pedestrian paths, footings of buildings, 4m
recreation areas, retaining wall footings - down slope of the land
application area
In ground swimming pools 6m
In ground water tanks 6m
Embankment cut/fill - down slope of the land application area 6m
CSI: 14096#2LakewayDriveCooroibah-Rev1