Compliance cert Form 15 ENGINEERNG 56 Reserve St Pomona

of 14

Page text shows just the words. Original shows the document exactly as it was published.

                                                                         11. CONSTRUCTION JOINTS, THE HARDENED CONCRETE SHALL BE THOROUGHLY                                  MINIMUM LAP LENGTH (FOR 25MPa, 32MPa & 40 MPa CONCRETE)
CONCRETE                                                                     SCRABBLED TO PRODUCE WELL-BOND INTERFACE WITH FRESHLY PLACED
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT                                                                                                                      MINIMUM CENTRE-TO-CENTRE SPACING OF BARS (mm)
                                                                             CONCRETE.                                                                       BAR
    AS3600, AS1379 AND RELEVANT AUSTRALIAN STANDARDS.                                                                                                                        50            100          150          200          250          300 (MAX.)
                                                                         12. WHERE NOT SHOWN ON THE DRAWINGS, NO CONSTRUCTION JOINTS SHALL BE
2. CONCRETE SHALL HAVE THE MAXIMUM AGGREGATE SIZE OF 20MM.                                                                                                   N12         700*              550          550          550          550              550
                                                                             MADE WITHOUT THE APPROVAL OF PEER ENGINEERS PTY. LTD.
3. CONCRETE SHALL HAVE A MAXIMUM SLUMP OF 80MM (± 15MM TOLERANCE).                                                                                           N16         1000*             800          700          700          700              700
                                                                         13. UNLESS NOTED OTHERWISE, HOLES, CHASES AND EMBEDED ITEMS INCLUDING
4. SAMPLING AND TESTING OF CONCRETE SHALL BE IN ACCORDANCE WITH AS1379                                                                                       N20        1400*             1200*         1100         1100         1100             1100
                                                                             PIPES AND CONDUITS WITH THEIR ASSOCIATED FITTINGS, SLEEVES SHALL NOT BE
    AND RELEVANT AUSTRALIAN STANDARDS. SAMPLES SHALL BE TAKEN FROM THE
                                                                             MADE IN A CONCRETE MEMBER OR STRUCTURE WITHOUT THE APPROVAL OF PEER             N24                          1550*        1400*        1400*        1400*            1400*
    CONCRETE AS AND WHEN DISCHARGED AFTER COMPLETION OF MIXING BUT PRIOR
                                                                             ENGINEERS PTY. LTD.                                                             N28                          2000*        1800*        1800*        1800*            1800*
    TO ANY SITE HANDLING. FOR STRENGTH GRADE ASSESSMENT, AT LEAST TWO                                                                                        N32                          2400*        2200*        2200*        2200*            2200*
    STANDARD CYLINDER SPECIMENS FROM EACH SAMPLE SHALL BE MADE AND
    CURED IN ACCORDANCE WITH AS1012.8.1 & AS1012.8.2.                       REINFORCEMENT                                                                    N36                          2900*        2700*        2700*        2700*
                                                                                                                                                           23. WHERE SHOWN WITH ( * ), THE LAP LENGTH FOR DEFORMED BARS SPECIFIED IN NOTE 22
                                                                                                                                                                                                                                                  2700*

5. WHERE A STRENGTH GRADE IS SPECIFIED, A SLUMP TEST IN ACCORDANCE WITH  14. REINFORCEMENT GRADE AND DUCTILITY CLASS:
                                                                                                                                                               CAN BE REDUCED BY 10% AND 20% FOR 32MPA AND 40MPA RESPECTIVELY.
    AS1012.3.1 SHALL BE PERFORMED ON EACH STRENGTH SAMPLES.                                                                                                24. THE LAP LENGTH OF HORIZONTAL BARS WITH MORE THAN 300MM OF CONCRETE CAST
6. UNLESS NOTED ON THE DRAWINGS OTHERWISE, MIN. CONCRETE STRENGTH AND                                            REINFORCEMENT                                 BELOW THE BARS SHALL BE INCREASED BY 30%.
    REQUIRED COVER FOR CORROSION PROTECTION SHALL BE IN ACCORDANCE WITH                                                     YIELD                          25. THE LAP LENGTH FOR A UNIT OF BUNDLED BARS SHALL BE BASED ON THE LAP LENGTH
    THE FOLLOWING:                                                                                                                       DUCTILITY
                                                                                       TYPE                 GRADE         STRENGTH                             OF LARGEST BAR WITHIN THE BUNDLE INCREASED BY
                                                                                                                                          CLASS
                                               MIN. STRENGTH  MIN. COVER                                                    (MPa)                          · 33% FOR A 4-BAR BUNDLE.
                   ELEMENTS
                                                   f'c (MPa)     (mm)        BAR PLAIN TO AS/NZS 4671        R250N           250            N              · 20% FOR A 3-BAR BUNDLE.
   FOOTING/CONCRETE PIERS (NON-AGGRESSIVE                                 BAR DEFORMED TO AS/NZS 4671        D500N           500            N              26. LAP REINFORCEMENT SHALL BE MADE ONLY IN LOCATIONS AS REQUIRED ON THE
                                                       25          50                                                                                          DRAWINGS OR AS PERMITTED BY PEER ENGINEERS PTY. LTD.
                      SOIL)                                                TRENCH MESH TO AS/NZS 4671        D500L           500             L
                                                                                                                                                           27. HEATING AND WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED WITHOUT THE
      SLAB ON GROUND (FOR TOP REINFORCEMENT)                                    SQUARE MESH TO AS/NZS 4671            D500L            500           L         APPROVAL FROM PEER ENGINEERS PTY. LTD.
     NON-RESIDENTIAL/ NON-PNEUMATIC TRAFFIC            40          TOP 45                                                                                  28. UNLESS SPECIFIED ON THE DRAWINGS, WHERE DEFORMED BARS END IN A STANDARD
                                                                              15. BAR LAYER SEQUENCE LEGEND:
   NON-RESIDENTIAL/ MEDIUM-PNEUMATIC TRAFFIC           32          TOP 45                                                                                      HOOK OR COG, BENDING OF REINFORCEMENT SHALL BE IN ACCORDANCE WITH AS3600.
           RESIDENTIAL/ EXTERNAL EXPOSURE              32          TOP 45                                                                                  29. REINFORCEMENT THAT HAS BEEN BENT AND SUBSEQUENTLY STRAIGHTENED OR BENT IN
                                                                                                  (C) THIRD LAYER          (D) LAST LAYER                      A REVERSE DIRECTION SHALL NOT BE BENT AGAIN WITHIN 20 BAR DIAMETERS OF THE
                RESIDENTIAL/ INTERIOR AREA             25           TOP 20                                                                                     PREVIOUS BEND.
   IF BOTTOM REINFORCEMENT IS SPECIFIED ON DRG.                                                                                                            30. REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY AND NOT NECESSARILY SHOWN IN
              COVER TO UNPROTECTED GROUND                        BOTTOM 50                                                                                     A TRUE PROJECTION.
                                                                                                                                                           31. THE MATERIAL, DESIGN & CONSTRUCTION OF FORMWORK SHALL COMPLY WITH AS3610.
           COVER TO WATER PROOF MEMBRANE                         BOTTOM 30                        (B) SECOND LAYER         (A) FIRST LAYER                 32. STRIPPING OF FORMS AND REMOVAL OF FORMWORK SUPPORTS FROM MEMBERS CAST IN
      SUSPENDED SLAB, BEAM, COLUMN & STAIR IN                                                                                                                  SITU SHALL BE IN ACCORDANCE WITH AS3600.
       INTERIOR ENVIRONMENTS (FULLY ENCLOSED                                                            'D' LAST LAYER                                     33. IN GENERAL, FORMS SHALL NOT BE STRIPPED OR ANY FORMWORK SUPPORTS REMOVED
                      WITHIN A BUILDING):                                                               'A' FIRST LAYER                                        UNTIL THE PART OF THE MEMBER THAT WILL BE LEFT UNSUPPORTED HAS ATTAINED
                        NON-RESIDENTIAL                32             40                                                                                       SUFFICIENT STRENGTH TO SUPPORT ITS OWN WEIGHT AND ANY SUPERIMPOSED LOADS
                             RESIDENTIAL               32             20                                'C' THIRD LAYER                                        DUE TO CONCURRENT OR SUBSEQUENT CONSTRUCTION WORKS.
                                                                                                       'B' SECOND LAYER                                    34. STRIPPING OF SOFFIT FORMS FROM REINFORCED SLABS CONTINUOUS OVER FORMWORK
      SUSPENDED SLAB, BEAM, COLUMN & STAIR IN
                                                                                                                                                               SUPPORTS:
                   EXTERIOR ENVIRONMENTS:                                     16. REINFORCEMENT BARS ARE DESIGNATED AS NO. OF BARS, CLASS, DIAMETER (MM), · FOR THE SUPERIMPOSED CONSTRUCTION LOAD LESS THAN 1.5KPA, THE MINIMUM PERIOD
         COASTAL (UP TO 1.0KM FROM COASTLINE)          40             45           BAR SPACING (MM), LAYER SEQUENCE E.G. 5 N12-250 (A).                        OF TIME BETWEEN CASTING OF THE CONCRETE AND THE COMMENCEMENT OF STRIPPING OF
     NEAR COASTAL (1.0 TO 50KM FROM COASTLINE)         32             40      17. TRENCH  MESH IS SHOWN AS NO. OF BARS, CLASS, DIAMETER (MM) E.G. 3-L11TM.     THE FORMS BETWEEN FORMWORK SUPPORTS SHALL BE AS FOLLOWS
                                                                              18. SQUARE AND RECTANGULAR MESH SIZES ARE PREFIXED WITH SL AND RL                                  MIN. LAP LENGTH
         INLAND (INDUSTRIAL OR TROPICAL AREA)          32             40
                                                                                  RESPECTIVELY E.G. SL92.
    INLAND (NON-INDUSTRIAL & TEMPERATE AREA)           32             25




                                                                                                                                                                   SPACING
                                                                              19. REINFORCEMENT AND VOID FORMERS SHALL BE FIXED IN CORRECT POSITION PRIOR




                                                                                                                                                                    BARS
 7. THE REQUIRED CONCRETE COVER TO THE REINFORCING STEEL DO NOT INCLUDE ANY       TO CONCRETING BY MEANS OF PROPRIETARY SPACERS, BAR CHAIRS AND                                                 DEFORMED BAR
      APPLIED SURFACE FINISH.                                                     LIGATURES TO ACHIEVE THE REQUIRED COVER. BAR CHAIRS SHALL BE SPACED AT
 8. CONCRETE SHALL BE HANDLED AND PLACED PROPERLY TO PRODUCE A                    MAXIMUM 800MM APART BOTH WAYS.                                           35. REMOVAL OF FORMWORK SUPPORTS FROM REINFORCED BEAM & SLAB NOT SUPPORTING
      MONOLITHIC MASS BETWEEN PLANNED JOINTS AND/OR THE EXTREMITIES OF THE 20. RAFT OR SLAB MESH SHALL BE LAPPED BY EMBEDDING AT LEAST 2 CROSS-BARS            STRUCTURAL ABOVE.
      ELEMENTS.                                                                   SPACED NOT LESS THAN 50MM APART AS SHOWN.                                · FOR THE SUPERIMPOSED LOAD LESS THAN 1.5KPA, THE PERIOD SHALL NOT BE LESS THAN
 9. CONCRETE SHALL BE MECHANICALLY VIBRATED AS TO LIMIT SEGREGATION,                                                                                           THAT GIVEN IN THE FOLLOWING TABLE.
      COMPLETELY FILL THE FORMWORK, EXPEL ENTRAPPED AIR AND CLOSELY                   MIN. 50mm                                                                 AVERAGE TEMPERATURE OVER THE PERIOD BEFORE   PERIOD OF TIME BEFORE STRIPPING
      SURROUND ALL REINFORCEMENTS, EMBEDMENTS & FIXINGS.                                                            AT LEAST 2 CROSS-BARS                                     STRIPPING (T°C)                             (DAYS)
 10. CURING OF CONCRETE SHALL COMMENCE IMMEDIATELY AFTER FINISHING OF ANY                                           TO BE LAPPED                                                  T > 20                                     4
      UNFORMED SURFACE. THE INITIAL CURING SHALL BE MAINTAINED FOR AT LEAST 7                                                                                                   20 ≥ T > 12                                  6
      DAYS. FLESHLY CAST CONCRETE SHALL BE PROTECTED FROM RAIN, RUNNING                                                                                                         12 ≥ T > 5                                   8
      WATER AND FREEZING OR DRYING CONDITIONS PRIOR TO HARDENING. SPRAYED     21. TRENCH MESH IN FOOTINGS SHALL BE ANCHORED BY THE WIDTH OF THE MESH AT 36. REMOVAL OF FORMWORK SUPPORTS FROM REINFORCED SLAB & BEAM IN MULTISTOREY
      MEMBRANE - FORMING CURING COMPOUNDS IF APPLIED SHALL COMPLY WITH AS         T-INTERSECTIONS AND L-INTERSECTIONS AND SHALL BE LAPPED BY 500mm AT          STRUCTURES SHALL BE PERMITTED ONLY IF THE CONCRETE HAS GAINED SUFFICIENT
      3799.11. AT CONSTRUCTION JOINTS, THE HARDENED CONCRETE SHALL BE             SPLICES.                                                                     STRENGTH AND THE DEGREE OF CRACKS AND DEFLECTIONS OF ALL SUPPORTED AND
      THOROUGHLY SCABBLED TO PRODUCE WELL-BOND INTERFACE WITH FRESHLY         22. REINFORCEMENT LAPS SHALL BE AS FOLLOWS:                                      SUPPORTING SLABS & BEAMS WILL NOT IMPAIR THE STRENGTH OR SERVICEABILITY OF
DO NOT SCALE FROM DRAWING
      PLACED
ALL SCALES ARE AS CONCRETE.
                  SHOWN (A3)                                                                                                                                   THE COMPLETED STRUCTURE.
REV.         DESCRIPTION    DATE    INIT.                                 CONTACT DETAILS               CLIENT                         PROJECT                                    TITLE                                          DRAWN         DESIGNED     DATE

 A     PRELIMINARY ISSUE   22.08.22 C.Y.                                  EMAIL    [email protected]
                                                                                                                                                                                                                                     C.Y.         C.Y.      AUG 2022
                                                                                                                                                                                                                                 CHECKED       APPROVED
 B     PRELIMINARY ISSUE   29.08.22 C.Y.                                  WEB      www.peerce.com.au
                                                                                                                                       PROPOSED NEW DWELLING GENERAL STRUCTURAL                                                      N.Z.
 0     FOR CONSTRUCTION    30.08.22 C.Y.                                  MOBILE   0425 885 440
                                                                                                                   LEIF O'BRIEN
                                                                          POST     PO BOX 5296                                           56 RESERVE STREET,    NOTES (SHEET 2)                                                   DRAWING No.                       REV.
                                                                                   ALGESTER, QLD 4115
                                                                                                                                          POMONA QLD 4568                                                                         PCE2211 - S02                      0
Log in to download the original file

Compliance cert Form 15 ENGINEERNG 56 Reserve St Pomona.pdf · 471 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.