STRUCTURAL STEEL WORK                                                          10. THE CONTACT SURFACES OF A JOINT USING A TENSION BOLT 22. UNLESS OTHERWISE SPECIFIED, THE COATING SYSTEM FOR
 1. ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE                            SHALL BE FREE FROM OIL, DIRT, LOOSE SCALE, RUST, BURRS,          STEEL WORK AFTER FABRICATION SHALL BE AS FOLLOWS:
      WITH CURRENT AS4100 STEEL STRUCTURES AND RELEVANT                            FINS AND OTHER DEFECTS TO ALLOW FOR A SOLID SEATING          · ALL  INTERIOR STEEL WORK TO BE PAINTED USING THE COATING
      AUSTRALIAN STANDARDS.                                                        OF THE PARTS IN THE SNUG-TIGHT CONDITION.                      SYSTEM    EHB4 EPOXY-HIGH BUILD OR EQUIVALENT COATINGS IN
 2. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY                                 11. ALL BOLTS IN 8.8/TB AND 8.8/TF BOLTING CATEGORY SHALL          ACCORDANCE     WITH AS2312 AND APPLYING ONE COAT OF ZINC
      TEMPORARY BRACING TO STABILIZE THE STUCTURE DURING                           BE INSTALLED AND TENSIONED USING THE PART-TURN                 RICH  PRIMER TO  0.075mm DRY FILM THICKNESS (DFT) AND A TOP
      THE CONSTRUCTION STAGES.                                                     METHOD OF TENSIONING AS PER AS4100 SECTION 15.2.5.2 OR A       COAT   OF HIGH BUILD EPOXY TO 0.2mm DFT.
 3. A COMPLETE SET OF STEEL STRUCTURAL SHOP DRAWINGS                               DIRECT-TENSION INDICATION DEVICE IN ACCORDANCE WITH          · ALL  EXTERIOR   STEEL WORK TO BE HOT-DIP GALVANIZED USING
      SHALL BE SUBMITTED TO PEER ENGINEERS PTY. LTD. FOR A                         AS4100 SECTION 15.2.5.3 AND MANUFACTURER'S                     THE  COATING  SYSTEM   HDG900 IN ACCORDANCE WITH AS2312.
      STRUCTURAL REVIEW PRIOR TO THE COMMENCEMENT OF                               SPECIFICATIONS.
      FABRICATION.                                                             WELD DESIGNATION
                                                                                                                                         TIMBER FRAMED CONSTRUCTION
                                                                                                                                                1. ALL TIMBER FRAMING SHALL COMPLY WITH:
 4. THE CONTRACTOR SHALL PROVIDE ADDITIONAL CLEATS,                            12. ALL WELDING SHALL COMPLY WITH AS/NZS 1554.1, AS/NZS
                                                                                                                                                   AS 1684 - RESIDENTIAL TIMBER FRAMED CONSTRUCTION AND
      BOLTS AND ATTACHMENTS NECESSARY FOR FIXING                                   1554.2 OR AS/NZS 1554.4 AS APPROPRIATE.
                                                                                                                                                   AS 1720 - TIMBER STRUCTURES
      ARCHITECTURAL AND OTHER ELEMENTS NOT SHOWN ON THE 13. UNLESS OTHERWISE NOTED,
                                                                                                                                                2. ALL MANUFACTURED PRODUCTS USED IN THE CONSTRUCTION
      STRUCTURAL DRAWINGS.                                                     · ALL WELDS SHALL BE MINIMUM 6MM CONTINUOUS FILLET
                                                                                                                                                   SHALL BE INSTALLED IN ACCORDANCE WITH THE
 MATERIALS                                                                       WELDS.
                                                                                                                                                   MANUFACTURERS SPECIFICATIONS AND GUARANTEE.
 5. UNLESS OTHERWISE SPECIFIED, ALL STRUCTURAL STEEL,                          · ALL BUTT WELDS IF SPECIFIED ON THE DRAWINGS, SHALL BE
                                                                                                                                                3. ALL TIMBER USED IN THIS CONSTRUCTION SHALL BE THE SIZE,
      BEFORE FABRICATION, SHALL COMPLY WITH THE                                  COMPLETE PENETRATION BUTT WELDS. THE DESIGN THROAT
                                                                                                                                                   TYPE AND STRESS GRADE SPECIFIED ON THESE DRAWINGS.
      REQUIREMENTS OF THE FOLLOWING STANDARDS:                                   THICKNESS OF A COMPLETE PENETRATION BUTT WELD SHALL
                                                                                                                                                   ALTERNATIVE DESIGNS SHALL BE SUBMITTED TO AND
                                                              TENSILE STRENGTH   BE THE THICKNESS OF THE THINNER PART / PLATE.
   STEEL STANDARD                 FORM          GRADE (MIN.)
                                                                    (MPa)                                                                          APPROVED BY PEER ENGINEERS PTY. LTD. PRIOR TO
                                                                               · ALL WELDS SHALL BE SP (STRUCTURAL PURPOSES) CATEGORY.
                           HOLLOW SECTIONS
                                                                                                                                                   CONSTRUCTION.
      AS/NZS 1163                                  C350              430       · MANUAL METAL ARC ELECTRODE SHALL BE E48XX OR W50X
                            (CHS, SHS & RHS                                                                                                     4. SUITABLY TREAT ALL TIMBER USED IN THIS CONSTRUCTION
                                                                                 WITH THE NONIMAL TENSILE STRENGTH OF WELD METAL OF
                               HOT ROLLED                                                                                                          AGAINST TERMITE, INSECT AND FUNGAL ATTACK, AS
                                                                                 480MPA
     AS/NZS 3679.1         SECTIONS (UB, UC,        300              440                                                                           APPLICABLE. EXTERNAL TIMBER ELEMENT EXPOSED TO
                                                                               14. ALL WELDS SHALL BE MADE IN THE SHOP. WELDING SHALL
                              PFC, EA & UA)                                                                                                        WEATHERING SHALL BE TREATED TO H3 LEVEL OR EQUAL TO
                                                                                   NOT BE CARRIED OUT WHEN THE WELDING SURFACES ARE WET
                            HT ROLLED BARS                                                                                                         ENSURE DURABILITY. WHERE EXPOSED DIRECTLY TO THE SUN,
     AS/NZS 3679.1        (ROUNDS, SQUARES          300              440
                                                                                   OR DURING PERIODS OF HIGH WINDS, UNLESS THE WELDER AND
                                                                                                                                                   FURTHER PROTECTION WITH A GOOD QUALITY PAINT SYSTEM
                                & FLATS)                                           THE WORK ARE PROPERLY PROTECTED. WELDS AT THE SITE
                                                                                                                                                   IS REQUIRED.
                           WELDED SECTIONS                                         SHALL BE APPROVED BY PEER ENGINEERS PTY. LTD.
     AS/NZS 3679.2                                  300              430                                                                        5. THE MAXIMUM MOISTURE CONTENT ANYWHERE WITHIN
                                (WB, WC)                                       15. ALL WELDS SHALL BE INSPECTED BY A QUALIFIED AND
                                                                                                                                                   SEASONED TIMBER SHALL NOT EXCEED 15 %.
                            PLATES & FLOOR                                         EXPERIENCED WELDING PERSONEL IN ACCORDANCE TO AS1554.
      AS/NZS 3678                                   250              410                                                                        6. HOT DIP GALVANIZED FIXINGS SHALL BE USED WITHIN 500M OF
                                 PLATES                                            FOR SP WELDING CATEGORY, THE EXTENT OF
                                                                                                                                                   AREAS EXPOSED TO SALT WINDS, EXPOSED TO WEATHER AND
 6. SUBSTITUTION OF STEEL GRADES AND ALTERNATIVE                                   NON-DESTRUCTIVE EXAMINATION TO DETERMINE THE LEVEL
                                                                                                                                                   / OR USED TO AFFIX CCA TREATED TIMBER.
      MATERIALS SHALL NOT BE PERMITTED WITH THE APPROVAL                           OF WELD QUALITY SHALL CONFORM TO THE FOLLOWING:
                                                                                                                  MAGNETIC
                                                                                                                                                7. HOLES DRILLED IN TIMBER FOR BOLTED FASTENERS SHALL BE
      OF PEER ENGINEERS PTY. LTD.                                                                    VISUAL                    ULTRASONIC FOR
                                                                                 VISUAL SCANNING                   PARTICLE                        OVERSIZED 2MM FOR BOLTS UP TO AND INCLUDING 16MM
 BOLT DESIGNATION                                                                                  EXAMINATION                   BUTT WELDS
                                                                                                                 EXAMINATION                       DIAMETER AND OVERSIZED 3MM FOR BOLTS 20MM AND
 7. BOLTS AND BOLTING CATEGORY SHALL COMPLY WITH THE
                                                                                                                             WHERE MIN. PLATES'    LARGER. WASHERS SIZED IN ACCORDANCE WITH TABLE 4.11 OF
      FOLLOWING:                                                                  100% OF WELDS   50% OF WELDS       NIL      THICKNESS = 20mm,    AS 1720.1 SHALL BE FITTED AGAINST ALL TIMBER FACES.
                                                                      TENSILE                                                10% OF BUTT WELDS
     BOLTING            BOLT         BOLT
                                             METHOD OF TENSIONING    STRENGTH 16. UNLESS STATED OTHERWISE, ALL CLEATS, GUSSET PLATES &          8. UNLESS DETAILED OTHERWISE TIMBER MEMBERS SHALL BE
    CATEGORY         STANDARD GRADE                                                                                                                FIXED WITH NOMINAL NAILS IN ACCORDANCE WITH AS1684.
                                                                       (MPa)
                                                                                   BRACKETS SHALL BE 10mm THICK.
       4.6/S        AS/NZS 1111       4.6         SNUG TIGHT            400    17. ALL HOLLOW SECTIONS SHALL BE SEALED BY 6MM END
       8.8/S        AS/NZS 1252       8.8         SNUG TIGHT             830       PLATES WITH 6mm CONTINUOUS FILLET WELDS UNLESS NOTED
      8.8/TB        AS/NZS 1252       8.8       FULL TENSIONING          830       OTHERWISE.
                                                FULL TENSIONING                18. SHOP SPLICE DETAILS AND LOCATIONS OF STRUCTURAL
      8.8/TF        AS/NZS 1252       8.8                                830
                                             (NON-SLIP FASTENERS)                  MEMBERS THAT ARE NOT SHOWN ON DRAWINGS SHALL BE
 8. UNLESS NOTED OTHERWISE,                                                        APPROVED BY PEER ENGINEERS PTY. LTD.
 · ALL BOLTS SHALL BE HOT-DIP GALVANISED HIGH STRENGTH 19. THE FABRICATION AND ERECTION OF THE STRUCTURAL STEEL
      STEEL BOLTS, M20 NOMINAL DIAMTER WITH 8.8/S BOLTING                          WORK SHALL BE SUPERVISED BY PEER ENGINEERS PTY. LTD.
      CATEGORY TO AS/NZS 1252.                                                     STEEL WORK SHALL BE FABRICATED AND ERECTED IN
 · ALL ASSOCIATED NUTS SHALL BE HOT-DIP GALVANIZED HIGH                            ACCORDANCE WITH AS4100 SECTIONS 14 &15 AND RELEVANT
      STRENGTH STEEL NUTS FOR STRUCTURAL ENGINEERING TO                            AUSTRALIA STANDARDS.
      AS/NZS 1252.                                                             20. UNLESS OTHERWISE NOTED, STEELWORK TO BE ENCASED IN
 · ALL ASSOCIATED WASHERS SHALL BE HOT-DIP GALVANIZED                              CONCRETE SHALL NOT BE PAINTED.
      HARDENED AND TEMPERED STEEL WASHERS FOR                                  21. ALL STRUCTURAL STEEL WORK NOT ENCASED IN CONCRETE
      STRUCTURAL ENGINEERING TO AS/NZS 1252.                                       SHALL BE PROTECTED BY A COATING SYSTEM. ALL STEEL
 9. HOLE SIZES SHALL BE 2MM LARGER THAN THE NOMINAL BOLT                           SURFACES SHALL BE ABRASIVE BLAST CLEANED TO CLASS
      DIAMTER. OVERSIZE AND SLOTTED HOLES ARE NOT                                  SA 2 1/2 BEFORE COATING IN ACCORDANCE WITH AS1627.4.
      PERMITTED WITHOUT APPROVAL FROM THE ENGINEER. THE                            THE PROCEDURE FOR ABRASIVE BLAST CLEANING SHALL BE
      HOLE    DIAMETER
DO NOT SCALE FROM DRAWING
                             IN A  BASE   PLATE  SHALL   NOT  BE  MORE   THAN      CARRIED OUT BY SUITABLY TRAINED AND SUPERVISED
      6MMARE
ALL SCALES   GREATER       THAN THE ANCHOR BOLT DIAMTER.
               AS SHOWN (A3)                                                       PERSONEL.
REV.         DESCRIPTION       DATE    INIT.                                          CONTACT DETAILS               CLIENT                                   PROJECT                                     TITLE   DRAWN         DESIGNED   DATE

 A     PRELIMINARY ISSUE      22.08.22 C.Y.                                           EMAIL    [email protected]
                                                                                                                                                                                                                     C.Y.         C.Y.    AUG 2022
                                                                                                                                                                                                                 CHECKED       APPROVED
 B     PRELIMINARY ISSUE      29.08.22 C.Y.                                           WEB      www.peerce.com.au
                                                                                                                                                            PROPOSED NEW DWELLING GENERAL STRUCTURAL                 N.Z.
 0     FOR CONSTRUCTION       30.08.22 C.Y.                                           MOBILE   0425 885 440
                                                                                                                             LEIF O'BRIEN
                                                                                      POST     PO BOX 5296                                                    56 RESERVE STREET,    NOTES (SHEET 3)              DRAWING No.                     REV.
                                                                                               ALGESTER, QLD 4115
                                                                                                                                                               POMONA QLD 4568                                   PCE2211 - S03                     0
Log in to download the original file

Compliance cert Form 15 ENGINEERNG 56 Reserve St Pomona.pdf · 471 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.