LANDPARTNERS


Existing Services Code

 column 1                                               column 2

 Specific Outcomes                                      Probable solutions (iif ceasabk

 Setbacks and easements                                 S1. / The footing of any structure or
 01 Development near a sewer, water main,               building is located clear of the zone of
 stormwater drain, overland flow path or associated     influence but no closer than 1.5rn
 structure does not-                                    (measured horizontally) from infrastructure
 a) adversely affect the function of the service;       including sewers, water mains and
 b) place an additional load on the service; and        stormwater structures;
 c) unduly increase future maintenance costs            AND
                                                        S7.2 No building or structure overhangs
                                                        the zone of influence;
                                                        AND
                                                        S1.3Finished surface levels maintain a
                                                        minimum of 600mm of cover, but no greater
                                                        than 3m of cover to the underground
                                                        infrastructure;
                                                        AND
                                                        S1.4If the existing surface level is altered,
                                                        surface level services including manholes
                                                        and inspection points are altered to match
                                                        the new surface level;
                                                        AND
                                                        S1.5AIterations are constructed in
                                                        accordance withPSP6 -Engineering Design
                                                        Standards - Water and Sewerage and
                                                        Section 4 of PSP5 -Engineering Design
                                                        Standards - Roads, Drainage and
                                                        Earthworks;
                                                        OR
                                                        Si .6 Existing services are relocated and
                                                        the design and construction of the relocated
                                                        services is in accordance with PSP6 -
                                                        Engineering Design Standards - Water
                                                        and Sewerage and Section 4 of PSP5 -
                                                        Engineering Design Standards - Roads,
                                                        Drainage and Earthworks.
 Compliance
 S1.1 Not Applicable - No building proposed
 51.2 Not Applicable - No building proposed
 Si .3 Not Applicable - No alteration to the ground level is proposed.
 S1.4 Not Applicable - No alteration to the ground level is proposed.
 S1.5 Complies - Alterations are constructed in accordance with PSP6 and section4 of PSP5.
 A1.6 Complies - Any relocated services will be constructed in accordance with PSP6 and section 4 of
 PSP5.
 02 Maintenance access is provided to all sewers,     S2. 1 A registered easement in favour of
 water mains, stormwater drains, overland flow paths  Council is created over all underground
 and associated structures.                           infrastructure located in private property;
                                                      AND
                                                      S2.2 The width of the easement is the greater of 3m or
                                                      the width of the zone of influence;
                                                        AND
                                                        S2.3The easement is centred over the centreline of the
                                                        infrastructure.
 Compliance
 S2.1 Complies - An easement will be created over the proposed infrastructure.
 S2.2 Complies - The easement will be 5m in width.
 S2.3 Complies - The easement will be centred over the centreline of the infrastructure.




                                         BRSS6220.000 Report for Lodgement                              47

Used in these records

About this file

File size
24.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application part 2 Application Forms REC11_0145.pdf · 24.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.