LANDPARTNERS
Existing Services Code
column 1 column 2
Specific Outcomes Probable solutions (iif ceasabk
Setbacks and easements S1. / The footing of any structure or
01 Development near a sewer, water main, building is located clear of the zone of
stormwater drain, overland flow path or associated influence but no closer than 1.5rn
structure does not- (measured horizontally) from infrastructure
a) adversely affect the function of the service; including sewers, water mains and
b) place an additional load on the service; and stormwater structures;
c) unduly increase future maintenance costs AND
S7.2 No building or structure overhangs
the zone of influence;
AND
S1.3Finished surface levels maintain a
minimum of 600mm of cover, but no greater
than 3m of cover to the underground
infrastructure;
AND
S1.4If the existing surface level is altered,
surface level services including manholes
and inspection points are altered to match
the new surface level;
AND
S1.5AIterations are constructed in
accordance withPSP6 -Engineering Design
Standards - Water and Sewerage and
Section 4 of PSP5 -Engineering Design
Standards - Roads, Drainage and
Earthworks;
OR
Si .6 Existing services are relocated and
the design and construction of the relocated
services is in accordance with PSP6 -
Engineering Design Standards - Water
and Sewerage and Section 4 of PSP5 -
Engineering Design Standards - Roads,
Drainage and Earthworks.
Compliance
S1.1 Not Applicable - No building proposed
51.2 Not Applicable - No building proposed
Si .3 Not Applicable - No alteration to the ground level is proposed.
S1.4 Not Applicable - No alteration to the ground level is proposed.
S1.5 Complies - Alterations are constructed in accordance with PSP6 and section4 of PSP5.
A1.6 Complies - Any relocated services will be constructed in accordance with PSP6 and section 4 of
PSP5.
02 Maintenance access is provided to all sewers, S2. 1 A registered easement in favour of
water mains, stormwater drains, overland flow paths Council is created over all underground
and associated structures. infrastructure located in private property;
AND
S2.2 The width of the easement is the greater of 3m or
the width of the zone of influence;
AND
S2.3The easement is centred over the centreline of the
infrastructure.
Compliance
S2.1 Complies - An easement will be created over the proposed infrastructure.
S2.2 Complies - The easement will be 5m in width.
S2.3 Complies - The easement will be centred over the centreline of the infrastructure.
BRSS6220.000 Report for Lodgement 47
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Application Forms REC11/0145Related documentApplication case desk ↗
About this file
- File size
- 24.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.