Skip to the record
Mmm.. taste the original NoosaWatch™

Council archive · source document

Development Application part 2 Application Forms REC11/0145

of 152

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (24.3 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

     b) Hospitals;                                          existing
     c) Education Type 4 uses, including stores             building;
     for valuable records or items of historic or           OR
     cultural significance; and                             55.3Where located in a High or Medium
     d) Service and utility uses, including                 Bushfire Hazard Area identified on Overlay
     electricity substations, major electrical              Maps OM1.4 to OM9.4, uses are designed to
     depots and water treatment plants.                     function effectively during and immediately after
                                                            bushfire events40,
     Compliance
     05 Not Applicable - No community uses and infrastructure uses are proposed.
     Hazardous materials                             S6. 1 Hazardous materials are not manufactured
     06 Public safety and the environment are not    and stored on the site
     adversely affected by the detrimental impacts
     of bushfire on hazardous materials
     manufactured or stored in bulk.
     Compliance
     S6.1 Not Applicable - No hazardous materials are stored on the site.
     13.34 Siting, design and construction
fl   07Uses and works including building works              57.1 Uses and works including building works
     are sited, designed and constructed to-                are sited-
     a) minimise the number of people and                   a) on lots greater than 2500m2;
     property subject to bushfire risk; and                 i) in locations of lowest hazard within
     b) maximise the protection of people and               the lot (Figure 13.5 provides
                                                            guidance): and
     front.                                                 ii) to achieve setbacks from hazardous
                                                            vegetation of 1.5 times the
                                                            predominant mature canopy tree
                                                            height or 1 Om whichever is the
                                                            greater; and
                                                            iii) 10m from any retained vegetation
                                                            strips or small areas of vegetation;
                                                            and
                                                            iv) so that the elements of the
                                                            development least susceptible to
                                                            fire are sited closest to the bushfire
                                                            hazard;
                                                            b) on lots 2500m2 or less - to maximise
                                                            setbacks from hazardous vegetation37
     Compliance
     07 Not Applicable - No buildings are proposed a         art of this development.
      13.35 Water supply for fire fighting
     O8An adequate and accessible water supply              58. 1 For premises not in a water service area-
     is provided for fire fighting purposes.                each lot has an accessible dam, swimming pool
                                                            or water tank accessible by the fire brigade that
                                                            contains at least 5000 litres of water
     Compliance
     S8.1 Complies - The site is in a water service area.
     13.36 Vehicle access and fire trails
     Firebreaks and fire access tracks                      S9. 1 Firebreaks are provided by-
     09 Firebreaks or fire access tracks provide-           a) a cleared road reserve not less than 20m
     a) adequate access for fire fighting and               wide located around the perimeter of the
     other emergency vehicles; and                          development;
     b) adequate width to minimise the risk of              OR
     fire crossover.                                        b) fire access tracks between the
                                                            development and surrounding vegetated
                                                            lands that-
                                                            i. are a minimum cleared width of 6m;
                                                            ii. have a maximum grade of 1 in 8
                                                            (12.5%) ;




                                           BRSS6220.000 Report For Lodgement                              70

Used in these records

About this file

File size
24.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application part 2 Application Forms REC11_0145.pdf · 24.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.