iii. have a formed pavement;
iv. have access at each end and in other
locations where necessary;
v. have passing areas and turning areas;
vi. have clearly identified access points
for emergency vehicles; and
vii. are located on public land or within
access easements that are granted in
favour of the Sunshine Coast Regional
Council and the Queensland Fire and
Rescue Service.
Compliance
59.1 Not Applicable - Refer to S 1 1.1.
13.37 Reconfiguring a Lot
General 510. 1 The proposed lots are not located on land
010 The safety of people and property are that is subject to Medium or High Bushfire
maintained by Hazard on overlay maps OM1.4-0M9.442;
a) Locating house site areas and other OR
C sensitive uses on that part of the land 510.2 The proposed lots are sited on land
least affected by the bushfire hazard; determined as low bushfire risk by a site specific
and bushfire hazard assessment.43
b) fire mitigation methods are used that are AND
adequate for the Potential Bushfire S10.3Additional lots are not created where their
Hn7nrd rating of th individual site. only vehicular access route is through a Medium
having regard to - or High Bushfire Hazard area shown on overlay
i. vegetation type; maps OM1.4-OM9.4
ii. slope;
iii. aspect;
iv. on-site and off-site fire hazard
implications of the development;
v. bushfire history;
vi. conservation values of the site; and
on)oing mainte nance.
Compliance
S10.1 Not Applicable - The proposal complies with S10.2.
510.2 Complies - The subject site is located within the Medium Bushfire Hazard overlay map. A
Bushfire Assessment has been undertaken which identifies the potential bushfire risk as very low due
to the extensive development in the Sunshine Beach area and the narrow foreshore reserve. As
assessment against the SPP 01 /03 provides a methodology for ground truthing the Potential Bushfire
Hazard of any site and immediate surrounds. As this site is not carrying any assessable vegetation, it
therefore scores less than 2 and no further assessment is required.
S10.3 Complies - The proposed lots achieve vehicle access via the existing handle which is outside
the bushfire overlay. Furthermore the attached Bushfire report identifies the site as being a very low
risk. Based on this it is clear vehicles can exit safely the site in the unlikely event of a bushfire.
BRSS6220.000 Report for Lodgement 71
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Application Forms REC11/0145Related documentApplication case desk ↗
About this file
- File size
- 24.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.