Council archive · source document
Appendix D - 52 Hastings Street, Noosa Heads - Change Application 17.1.19 · 51994.1435.01
Attached to the e-mail Change to DA (Include Outdoor Dining Area & Awning Structure) 51994.1435.01.
9/1 Nerang St Nerang QLD 4211 PO Box 1019 Nerang QLD 4211 PH: (07) 5596 1308 FAX: (07) 5596 13028 Gold Coast Building Approvals Conditions and advice notes ~— class 1 & 10a BA21406 Awning / annex to Cafe Le Monde CERTIFICATES: - BA21406 — As constructed roofed area. On completion, we will need certificates for the following. Note that certificates not in the appropriate form 15 or 16 format will not be accepted. ® Termite barrier @ Engineer’s Certification form 16 for structural adequacy Truss Certificate Pre-nail frame certificate Wet area sealing Glazing Certificate (windows, shower & mirrors) Smoke alarms installation Energy efficiency installation Surveyor (for set-out or height) Fire Resistant Mineral Wool Certificate (For Fire Wall) STORMWATER Roof water is to be connected to a system discharging to ane of the following points:- e — the street channel ® — a Council stormwater drain ® Legal point of discharge Concentration of water and discharging it across property boundaries is unlawful. This includes water and discharge caused by remodelling of the site contours. INSPECTIONS of the following building elements will be required: ki Final Additional/re-inspections are charged at $125.00 + GST NOTE — Only Gold Coast Building Approvals can issue a clearance to allow footings to be poured, failure achieve this inspection result from us before pouring concrete requires us to notify the BSA. A structural engineer can still inspect the structural aspects but we are required to issue the footing Clearance. Slab & frame can be inspected by competent persons subject to prior consent and advice of the persons inspecting. For Inspection Bookings contact us on 55 966 319 Bush Fire (medium risk if 40m clear) Timber floor to have minimum 600mm _ ground clearance or be fire retardant timber. Cladding within 400mm of ground to be non- combustible or fire-retardant treated. Windows require screening with steel, bronze or aluminium mesh with gaps =<1.8mm External doors must be fitted with- a) weather strips or draught excluders to prevent the build-up of burning debris beneath the door; and b) tight fitting screen doors with corrosion resistant steel, bronze or aluminium mesh with a maximum aperture size of 1.8mm Vents and weepholes must be protected with spark guards made from corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of 1.8mm, Timber deck gaps to be 5mm minimum and be separated from building so as not to spread fire to the building. Water & gas Service pipes to be metal and buried >300mm under ground. Gaps under corrugations or ribs of sheet roofing must be sealed or protected at the wall or fascia line by- (i) fully sarking the roof; or (iD) providing corrosion resistant steel, bronze or aluminium mesh with a maximum aperture size of 1.8mm, profiled metal sheet, neoprene seal or compressed mineral wool. FLOOD LEVEL of -----m AHD has been set for the is property (----m + 0.3m freeboard), ground level has been advised as -----| m, a surveyors certification regarding the finished floor level will be required. The Waterfront setback for this property is N/A This approval is subject to compliance with Local Authority Local Laws, By-laws and Town Planning provisions for the GCCC PLANS ON SITE : A complete set of plans endorsed by us should be kept on site to facilitate the inspections. AMENDMENTS TO THE PLANS AND RE- INSPECTIONS usually attract an additional fee. The Design Wind Speed is N3 GENERAL ADVICE (refer also to notes on drawings in red) © Balustrades generally need to be 1 metre high with maximum gaps of 125mm, Non-climbable over 4.0m. In stairs the height can be reduced to 865mm. ® — Stairs must have a suitable non-slip finish or non- skid strip at the nosing’s, Gloss polyurethane is not suitable as a stair finish. @ Second floor windows should have fall protection considered, we recommend restricting accessible openings (windows over baths, windows <1,0m) to 125mm opening or with fixed security screens. e® Wire Balustrade construction to comply with table 3.9.2.1 BCA, over 4.0m fall handrails must be non-climbable. ® ~The following must be marked grade A safety glass, refer to AS 1288-2006 for details: -Mirror Wardrobe doors -Bathroom mirrors -All bathroom & ens windows <2.0m high
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix D - 52 Hastings Street, Noosa Heads - Change Application 17.1.19.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.5 MB (small file)
- File type
No other editions are linked here.