11.   Buildings and structures (including swimming pools, sheds, tennis courts or outbuildings) are
      not constructed under overhead electricity transmission lines, or within any easements.
12.   All manholes, inspection pits and grates are to be raised to finished surface levels and kept
      free of cover and be visible at all times to ensure prompt access in case of emergency.
Relevant Period
The Development Permit for a material change of use lapses if the use has not happened by 5
March 2013, unless an application to extend the currency is approved by the Iconic Panel.
Land Development
13.   A vehicular access driveway to serve the site shall be constructed from the Grosvenor Terrace
      frontage of the site generally in accordance with Site Plan KSY Sheet 1 and 13 by Ausmar
      Homes dated 15 January 2009 except as modified herein.
14.   The driveway shall be designed and constructed to Council’s design standards and to grades
      that prevent vehicles from scraping and/or bottoming whilst also allowing pedestrians
      movements along the footpath without any step or level difference. Should any driveways be
      constructed to grades that do not comply with AS/NZS 2890.1-2004 Council will require that
      the driveway be removed and reconstructed to levels that do comply.
      Please note, a step between the driveway and the surrounding area shall be avoided, as it is
      preferred to have the footpath continue at a constant grade to minimise the potential for
      pedestrians to trip or fall.
15.   To ensure pedestrian safety between vehicles exiting the site and pedestrians on the property
      frontage, the driveway and any associated fencing or vegetation near the driveway shall
      comply with the minimum sight line requirements as defined in AS 2890.1, section 3.2.4. The
      applicant shall demonstrate compliance by illustrating these sight lines on the plans submitted
      for Building Works approval.
16.   A Road/Footpath Permit shall be completed and submitted for the construction of the access
      driveway in accordance with Council’s Local Law No.8. If approval is given the driveway shall
      be constructed in accordance with Council’s standard drawings, which will be provided at time
      of approval.
Roof Water & Stormwater Drainage
17.   Prior to issue of Building Approval, the sites Rapid Infiltration Pit (RIP) must be demolished
      and a new RIP constructed in strict accordance with the specifications detailed on the
      information request response letter to Suncoast Building Approval from Steve Harrison of
                                                     th
      TATE Professional Engineers Pty Ltd dated 19 January 2009.
      An RPEQ must provide a signed letter to Council prior to issue of Building Works Approval to
      certify that the RIP has been constructed in accordance with the response letter to Suncoast
                                                                                                 th
      Building Approval from Steve Harrison of TATE Professional Engineers Pty Ltd dated 19
      January 2009.
18.   Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank that
      is installed to ensure water from the rainwater storage system or tank is used for external uses
      (such as watering gardens, irrigation, ornamental ponds, water features, topping-up swimming
      pools, outdoor cleaning, etc) and for internal (ground floor) use in washing machine cold taps
      and toilet cisterns. All rainwater tanks are to be designed and installed in accordance with the
      Queensland Development Code (QDC) current at the time of building approval, and shall be
      part of the plumbing application for approval. The location and capacity of the tanks shall be
      clearly shown on the plans submitted for Building Works approval and any overflow shall be
      directed to Rapid Infiltration Pit located within the site.




                                                                                     Page 3 of 6

Used in these records

About this file

File size
32 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Council's Recommendation to Noosa Iconic Panel - 010.2008.00001927.001 [As Published].pdf · 32 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.