In reply please refer to:
Our: Troy Paulsen
At: Sunshine Coast
Our Ref: SC-8839

     24th February 2021

     Noosa Shire Council
     PO Box 141
     Tewantin QLD 4565


     RE:       SITE         BASED   STORM   WATER    MANAGEMENT          PLAN     FOR    PROPOSED
     APPARTMENTS AT 31 BOTTLEBRUSH AVE, NOOSAVILLE


     1. INTRODUCTION
     The proposed development consists of a multi-apartment development and associated car
     parking. The site is fronting Bottlebrush Ave to the South West and existing residential
     allotments to the remaining boundaries. The site is currently occupied by a single two story
     residential dwelling with its associated access driveway. The total site area is 506m 2 and has an
     approximate fraction impervious of 46% (Fi = 0.46).


     2. STORMWATER CONNECTION
     Under existing conditions, stormwater runoff discharges to the kerb and channel fronting the
     subject site, before falling to the North West before flowing into the existing 300mm diameter
     underground stormwater network. The proposed stormwater will continue to discharge into the
     Bottlebrush Ave kerb and channel in accordance with local council’s discharge flow rates of
     maximum 25L/s.


      3. STORMWATER QUANTITY
     The proposed development will increase the impervious nature of the site compared to pre-
     development to a fraction impervious of 80% (Fi = 0.80). Therefore, peak flow mitigation is
     proposed to limit minor and major flows (50%, 20%, 10%, 5%, 2% & 1% AEP), to that of the
     pre-development scenario to ensure the downstream pipe capacity is not worsened.

Log in to download the original (Site Based Sotrmwater Management Plan.PDF)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 4 pages

Page 2

Detention will be incorporated in the post-development scenario for the minor events that will
discharge into the existing kerb and channel. XP-STORM V2017.2 was used to determine the
detention volume required and the results are illustrated in Table 1.1. Table 1.1 illustrates that
10kL of detention with two 100mm diameter outlet mitigates the minor event discharge to less
than the required 25L/s flow rate and less than the pre-development scenario.


A concept stormwater management plan has been provided in Attachment 1, and hydrographs
have been attached in Attachment 2.


                   AEP (ARI)    Pre-Development         Post-Development Peak
                                Peak Flows              Flows (Mitigated)

                   50% (2yr)    0.024                   0.015
                   20% (5yr)    0.033                   0.018
                   10% (10yr)   0.043                   0.020
                   5% (20yr)    0.049                   0.021
                   2% (50yr)    0.046                   0.023
                   1% (100yr)   0.051                   0.025

                           Table 1.1 – Pre vs Post Development Discharge

Page 3

                                                                               Subject Site:
                                                                           31 Bottlebrush Ave,
                                                                                Noosaville




                                                                                    N

                                   Figure 1.1 Site Location
Should you have any further requirements in relation to the above matters, please contact the
undersigned.




Yours Faithfully,




Troy Paulsen
RPEQ No. 6990
For and on behalf of
Empire Engineering Pty Ltd

Page 4

ATTACHMENT 1: Concept Stormwater Management Plan


[OCR of page images]
ATTACHMENT 1: Concept Stormwater Management Plan

td te
bbb beg ed OPLETETTELELTTELL EDIE by

OCELELLEEELELELEELELELEA EEL EDEL ‘Fi
COLELELELEELELELELEELETEDELLTLELELEEE PAGE
OLEULLLELEELELELELEELELELELLELELEED
tt tt Fi AOLELELEELELELELEELELELELEE ED
CL IELELEELELELEELELEE LGD ELEE

tes

 

 

 

CbEttE ELS
tH: Clipe ch ti tests et ttt tt ér be
A ‘C4 COCEELELEEE LET:
AOL EDELLTLELEELEL ELLE EES
‘t OLE AIEEE EE: tht eg

 

‘onee, ee eee tts
tilt tt tt tt LETHE ELE
sthtirlbistttttbheg
OCPEEE,
bP IEEE DRL ETE
tts
SPbEt tty

 

 

2 > ‘te

 

Post Outlet >

 

Page 5

ATTACHMENT 2: Hydrographs




                            Pre-Development




                            Post-Development


[OCR of page images]
ATTACHMENT 2: Hydrographs

Node - Pre-Development

 

 

 

 

= = =
ECN_50Opct_15min_2[Max 0.024] ECN_20pct_15min_2[Max 0.033] ECN_10pct_30min_3[Max 0.043]
ss = =
ECN_5pct_30min_3[Max 0.049] ECN_2pct_30min_6[Max 0.046] ECN_1pct_30min_6[Max 0.051]
0.050
0.045
0.040
0.035
> 0.030
So
it 0.025
0.020
0.015
0.010
0.005
0.000
Fri 0:30 1:00
Jan 2016 Time
Pre-Development
Conduit 2/100mm Dia from 10kL Tank to Post Outlet
= = =
ECN_SOpct_15min_10[Max 0.015] ECN_20pct_15min_10[Max 0.018] ECN_10pct_30min_3[Max 0.020]
= — —
ECN_5pct_30min_3[Max 0.021] ECN_2pct_30min_6[Max 0.023] ECN_1pct_30min_6[Max 0.025]
0.025
0.020
0.015
&
we
0.010
0.005
0.000
Fri 0:30 1:00
Jan 2016 Time
Post-Development

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.