Council archive · source document
SUPERSEDED Decision Notice - Change to an Existing Approval - 010.2003.00221172.002 [As Published] · 132003.221172.2
2003/221172
11. The development must not exceed a building height of three (3) storeys and twelve (12)
metres measured vertically at any point from both the natural ground level and the finished
ground level, in accordance with the requirements of the Schedule to the Planning Scheme.
12. Deleted.
13. Deleted.
14. The proposed development shall have all kitchen, laundry and bathroom fittings that comply
with the AAA Water Conservation Rating System as defined by the AS/NZS 6400 (Water
Efficient Products - Rating and Labelling 2003) and AS/NZS 3500 (National Plumbing and
Drainage Standard Part 1.2). All tap ware and shower roses shall not exceed a maximum flow
of 9 litres per min. Dishwashers and washing machines are excluded from this requirement.
15. Security in the form of a cash bond or trading bank guarantee to the sum of $20,000 must be
submitted, to secure performance of all conditions of this approval, prior to the issue of a
Development Permit for operational works. The cash bond or trading bank guarantee will be
returned on performance of the conditions of approval less any costs incurred by Council in
respect of enforcing performance of this permit.
16. The requirements of this development approval are to be effected, prior to the use of the
premises. Council reserves the right to call upon the bond or guaranteed sum referred to in
this approval to effect compliance with conditions.
17. This Development Permit for a Material Change of Use lapses if:-
17.1. the use has not commenced by 16 December 2010, unless application is made and
approved by Council for an extension; or
17.2. the use of any premises pursuant to the Development Permit ceases.
18. The developer must obtain all of the other Development Permits referred to in the Decision
Notice, prior to obtaining a Development Permit for building works.
Land Development
Vehicle Access
19. A 4.5 metre wide vehicular access driveway to serve the development shall be constructed
from the Elanda Street frontage of the site.
The driveway shall be designed and constructed to Council’s design standards and to grades
that prevent vehicles from scraping and/or bottoming. Should any driveways be constructed to
grades that do not comply with AS2890.1-1993 and AS2890.2-1989, Council will require that
the driveway be removed and reconstructed to levels that do comply.
20. All vehicles shall enter and leave the site in a forward direction.
Carparking
21. Carparking shall be provided within the site as shown on drawing number 4/1918/S1c dated
2/8/04 by Adrian Pooley & Associates Pty Ltd, except as modified herein.
22. A minimum of 4 covered carpark spaces shall be provided on site and the carparking area
shall be designed to comply with the provisions of AS 2890.1-1993 with a minimum head
clearance (headroom) at any point of 2.2m.
23. The column located to the south west of carpark space number 3 (in-line with the garage wall
to the west of carpark space 3) largely inhibits the forward manoeuvre of vehicles that have
reversed from spaces 3 & 4. As such, this column shall be relocated so that it does not inhibit
any vehicle manoeuvres.
Page 3 of 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Decision Notice - Change to an Existing Approval - 010.2003.00221172.002 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 69 KB (small file)
- File type
No other editions are linked here.