Council archive · source document
Viridian III Technical Specification OPW1 [As Published] · 142008.256
VIRIDIAN III - Landscape Works 15.1.5 PRUNING Do not prune tree stocks. In the event of pruning or tree surgery a qualified Noosa Shire Council approved arborist shall undertake these works at the approval of the Builder. 15.1.6 MULCHED SURFACES Organic Mulch: Mulched surfaces are to be kept clean and tidy and free of any deleterious material and foreign matter. Reinstate depths to a uniform level of 100mm with organic mulch equal to medium grade hoop pine bark mulch, free of any wood material impregnated with CCA or similar toxic treatment. Frequency: monthly 15.1.7 PEST AND DISEASE CONTROL Spray for pests and disease infestations when the pest and fungal attack has been positively identified and when their populations have increased to a point that will become detrimental to plant growth. Apply all pesticides to manufacturer's directions. All safety controls shall be implemented prior to chemical spraying and site administration notified of the intent to spray. Frequency: weekly inspection 15.1.8 FERTILISING Apply a balance of man made and natural slow release fertiliser to all planting areas. A slow release fertiliser equal to Nutricote or other granular fertiliser (e.g. Osmocote), 3 month formulation, 16 - 4. 4- 8.3 NPK should be used as well as a natural fertiliser such as Dynamic Lifter or equal. The fertilising program shall be determined on the basis of the periodic soil test results, and amended as necessary. Soil tests shall be carried out by the contracts on a 2 monthly basis. Generally check for signs of nutrient deficiencies (yellowing of leaves, failure to thrive), and adapt fertiliser regime to suit. Fertiliser should be applied at the beginning and the end of the (summer) growing season. 15.1.9 SOIL MIXES Soil depths are to be maintained at the specified depths. Replenish any areas of subsidence with topsoil equal to that nominated in the Specification. 15.1.10 SUBSOIL DRAINS Ensure drains are working in an efficient manner, free from sediment build-up, litter and obstructions. Flush out and clean drain as required: Reinstate damaged or sunken drains. EDAW Aust Page 45 February 2008
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Viridian III Technical Specification OPW1 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 133 KB (small file)
- File type
No other editions are linked here.