Log in to see the plans as drawn Concrete-look Timber Concrete-look 190 series blockwork with
60/60/60 fire render finish battens render finish selected render finish
separation wall
Rooftop Level
RL 23.484 m
Metal roofing, fascias, barges and Hinged aluminium Hardies Axon FC sheeting with Velux Skylights
gutters in Colorbond Basalt privacy blades Cladding cover-strips
Upper Level
RL 20.784 m
um height
6640
8m maxim
Garage Level
RL 18.184 m
Ground Floor Level
RL 17.464 m
Under-croft
Aluminium batten
balustrade
Timber
battens
Stone
Lower Level steppers
RL 14.464 m
Velux Skylights Concrete-look
render finish
Metal roofing, fascias, barges and
gutters in Colorbond Basalt
Rooftop Level
RL 23.484 m
2 Elevation
Elevation SE 1 : 100
FC sheeting with
cover-strips
Upper Level
RL 20.784 m
190 series blockwork with
selected render finish
Aluminium batten
balustrade
Garage Level
RL 18.184 m
Ground Floor Level
RL 17.464 m
Hardies Axon
Cladding
Lower Level
RL 14.464 m
Galv. steel posts to
engineers specification
1 Elevation
Elevation SW 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ELEVATIONS DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.061
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:25 PM