Log in to see the plans as drawn 6000 23210 4500
8m m
ax im
rear setback
um h
boundary
eigh
front setback
t
190 series blockwork with Concrete-look Timber Concrete-look
selected render finish render finish battens render finish
Rooftop Level
RL 23.484 m
boundary
Velux Skylights FC sheeting with Hardies Axon Fixed angle aluminium Metal roofing, fascias, barges and
cover-strips Cladding privacy blades gutters in Colorbond Basalt
2700
5500
Upper Level
RL 20.784 m
2600
Garage Level
RL 18.184 m
720
Ground Floor Level
RL 17.464 m
Aluminium batten balustrade
1 Elevation Timber
3000
battens
Elevation NW 1 : 100
Stone Lower Level
steppers RL 14.464 m
190 series blockwork with
selected render finish
Timber batten Concrete-look
privacy screens render finish
Concrete-look Concrete-look
render finish render finish
timber batten screen timber batten screen
suspended conc. planter suspended conc. planter
Upper Level
RL 20.784 m
Concrete-look
render finish
Aluminium batten Aluminium batten balustrade
balustrade
Garage Level
RL 18.184 m
Timber battens to tilt Concrete-look Selected finish to tilt Concrete-look
panel garage door render finish panel garage door render finish
2 Elevation
Elevation NE 1 : 100
No. Description Date
A Approval Issue A 16/10/2020 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty ELEVATIONS DRH
B
C
Approval Issue C
Approval Issue D
18/11/2020
04/12/2020
049 1 : 100
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd
www.dennishillarchitect.com
D
E
Approval Issue E
Approval Issue F
10/12/2020
10/02/2021 BA.060
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 10/02/2021 8:05:19 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.