Original source · versioned page text
Town Planning Assessment Report
any property already containing
more than one dwelling;
is accompanied by sufficient car
parking.
Service and utilities AO5.2 AO5.2 - Complies
PO5 Where there is no reticulated water
Development is provided with: supply, the premises is serviced with a Water tank capacity will exceed
60,000L.
rainwater tank with the following
a) a level of infrastructure and minimum water supply capacity:
services that is appropriate to
its setting and sufficient for the a) for dwellings with no more than 3
intended use; bedrooms – 45,000 litres; or
b) an effluent treatment and b) for dwellings of more than 3
disposal system that does not bedrooms or where including
have an adverse effect a secondary dwelling on the
on ecologically important same premises – 60,000 litres.
areas or water quality; and
c) adequate onsite water storage AO5.3
to support the efficient use of If located on a lot where reticulated AO5.3 - Complies
water and is adequate for sewerage is not available to the lot, The dwelling will be connected to
everyday use of the occupants. the dwelling is connected to an on- an onsite effluent disposal system.
site effluent treatment and disposal
system.
AO8 - AO14 - Not Applicable
An existing driveway will be used to access the proposed dwelling. No additional works are proposed.
Bushfire Hazard Management AO15 AO15 - Complies
PO15 Within a bushfire hazard area where
The proposed dwelling is located
Where located in a Bushfire Hazard there is no reticulated water supply,
Area as shown on the Bushfire the premises has: outside of the bushfire hazard area
applying to the land. Further, the
Hazard Overlay Map in Schedule 2
dwelling will have access to water
and not in a water service area, an a) an accessible dam, swimming
tanks and dams that exceed
adequate, reliable, safely located pool or water tank available for
5000L in capacity.
and freely accessible water supply firefighting purposes with an
is provided for fire fighting purposes, onsite water volume of not less
which is in addition to day to day than 5,000 litres; and
water supply.
b) a water supply outlet pipe 50
millimetres in diameter and fitted
with a standard fire brigade fitting
connected to the water supply
(other than where the water
supply is in a swimming pool or
dam).
Flood Hazards AO16.1 AO16.2 - Not Applicable
PO16 Where the development is located in
Development is designed and sited the Flood Hazard Area as shown The dwelling is not located in a
to ensure risk to people and on Flood Hazard Overlay Map in Flood Hazard Area.
property from flooding is avoided or Schedule 2, the finished floor level is at
minimised. least 300mm above the DFE
Or
Page 13 of 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.