Specific Outcomes Probable Solutions Proposal
d) unacceptable risks to personal and head is not more than 7m; Marina lease area.
public safety.
AND Not applicable – The proposed deck is
S9.4 A pontoon head has a maximum wholly contained within the Noosa
width of 3m and a maximum length of Marina lease area.
5m; (Refer Figure 14-31)
Figure 14-31
S9.5 For “Y” and “T” shaped jetty Not applicable – The proposed deck is
heads— wholly contained within the Noosa
a) a maximum area 10.5m2 excluding Marina lease area.
any walkway is provided; and
b) a walkway with a minimum length of
3m is provided (Refer Figure 14-32);
Figure 14-32
S9.6 Gangways and walkways serving Not applicable – The proposed deck is
jetties and pontoons have at least one wholly contained within the Noosa
rigid handrail fitted and meet the Marina lease area.
following—
a) For detached houses – a minimum
width of 750mm and a maximum width
of 1.5m;
b) For other residential uses –
i. the gangway for single berth pontoons
has a minimum width of 900mm;
ii. the gangway for multiple berth
pontoons has a minimum width of 1.2m
if fitted with one handrail and 900mm if
fitted with a handrail on each side;
iii. the primary walkway to multiple
berth pontoons has a maximum width of
1.5m; and
iv. The maximum width of the gangway
is 1.5m;
AND Not applicable – The proposed deck is
S9.7 In Noosa Sound, where quaylines wholly contained within the Noosa
are set, a jetty or pontoon does not Marina lease area.
extend into the watercourses beyond
the quayline32;
OR Not applicable – The proposed deck is
S9.8 Where no quaylines are set, the wholly contained within the Noosa
maximum distance a jetty or pontoon Marina lease area.
extends into the watercourse is 10m,
unless it can be demonstrated that a
distance in excess of 10m is essential to
safely access the jetty.
14.173 Design, Construction and Safety – Boat Ramps
O10 Boat ramps are designed and S10.1 Where there is an existing Not applicable – the proposal is not
constructed to— revetment wall— for a boat ramp.
a) allow access by a wheeled boat a) the levels of a boat ramp surface at
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Assessment Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.