Original source · versioned page text
Bushfire Risk Assmt & Risk Mngt Plan for house at 8 Hinterland Cl, Tinbeerwah Revision 1 June 2022 ENAM
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn Ecological Natural Area Management
7 Bushfire risk management solutions and recommendations
7.1 Bushfire hazard mitigation recommendations: Considerations
As shown above, the house:
• Is in a Potential Bushfire Impact Buffer area on The Noosa Plan Bushfire Overlay,
• Is in a Potential Bushfire Impact Buffer area on Queensland potential bushfire intensity
mapping,
• Is in an area assessed as Potential Bushfire Impact Buffer Class as assessed using the
protocol of A new methodology for state-wide mapping of bushfire prone areas,
• Is confirmed as being in a Bushfire Prone Area,
• Is assessed with a minimum Asset Protection Zone width of 23m and,
• Is assessed as with a construction requirement of:
◦ BAL 19 for the east, south and north building elevations and
◦ BAL 12.5 for the west building elevation.
Accordingly, this section will recommend bushfire mitigation requirements for the above
assessments with reference to legislative requirements detailed in:
• The Noosa Plan 2020 Bushfire Overlay Code,
• Australian Standard AS 3959 Construction of Buildings in Bushfire Prone Areas and
• State Planning Policy 2017.
7.2 Recommendations for Part E: Natural hazards of Qld State Planning Policy 2017
It is recommended that, notwithstanding that the proposed building location is in an area of
Potential Bushfire Hazard:
• The building siting, construction, firefighting resources appropriately mitigates the potential
bushfire Hazard as required by the SPP
• The development does not unduly burden emergency services as there is good access for
firefighting appliances, good fire fighting space, good water supply and contributes only one
extra building in the emergency services area
• The building and the cleared and hard-standing areas decreases the severity of a bushfire
on the lot and therefore does not increase severity of the bushfire Hazard and,
• There will be no hazardous material stored on the lot and
• An Asset Protection Zone with a minimum width of 23m is available.
7.3 Recommendations for Australian Standard AS3959
Australian Standard AS3959 Construction of buildings in bushfire-prone areas specifies Deemed to
Satisfy bushfire resistant methodologies based on the assessed Bushfire Attack Level.
It is recommended that:
• The building solution for the east, south and north building elevations to address the
Deemed to Satisfy requirements of Sections 3 and 6 of Australian Standard AS3959-2018
Construction of buildings in bushfire-prone areas and
• The building solution for the west building elevation to address the Deemed to Satisfy
requirements of Sections 3 and 5 of Australian Standard AS3959-2018 Construction of
buildings in bushfire-prone areas
Bushfire Risk Assessment and Management Plan for a house at 8 Hinterland Cl, Tinbeerwah June 2022
20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.