Recommendations
Recommendations for Part E: Natural hazards of Qld State Planning Policy 2017
It is recommended that, notwithstanding that the proposed building location is in an area of
Potential Bushfire Hazard:
• The building siting, construction, firefighting resources appropriately mitigates the potential
bushfire Hazard as required by the SPP
• The development does not unduly burden emergency services as there is good access for
firefighting appliances, good fire fighting space, good water supply and contributes only one
extra building in the emergency services area
• The building and the cleared and hard-standing areas decreases the severity of a bushfire
on the lot and therefore does not increase severity of the bushfire Hazard and,
• There will be no hazardous material stored on the lot and
• An Asset Protection Zone with a minimum width of 23m is available.
Recommendations for Australian Standard AS3959
Australian Standard AS3959 Construction of buildings in bushfire-prone areas specifies Deemed to
Satisfy bushfire resistant methodologies based on the assessed Bushfire Attack Level.
It is recommended that:
• The building solution the east, south and north building elevations to address the Deemed
to Satisfy requirements of Sections 3 and 6 of Australian Standard AS3959-2018
Construction of buildings in bushfire-prone areas
• The building solution for the west building elevation to address the Deemed to Satisfy
requirements of Sections 3 and 5 of Australian Standard AS3959-2018 Construction of
buildings in bushfire-prone areas
Recommendations for the Noosa Plan 2020 Bushfire Overlay Code
It is recommended that:
• The house is sited in a low hazard area in the lot and achieves a setback of 10 metres from
any retained vegetation.
As the house is in a Potential bushfire Impact Buffer Class area and a reliable reticulated water
supply is not available, it is recommended that:
• The premises to have a minimum water supply capacity of 5,000 litres dedicated for fire
fighting purposes which is sourced from a separate tank, a reserve section in the bottom
part of the main water supply tank, a swimming pool installed immediately upon
construction or a permanent dam.
Other recommendations for building siting and landscaping
It is recommended that:
• The building to have a bushfire fuel free zone around the house,
• The building be constructed with a minimum of lodgement points for burning debris and
• On-going maintenance of the building be conducted.
See Sections 7.4, 7.5 and 7.6 of this report
Bushfire Risk Assessment and Management Plan for a house at 8 Hinterland Cl, Tinbeerwah June 2022
6
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.