XX

General Notes to External Windows & Doors W#.

01

02

03

04

05

06
07

08
09

10

1

Gel
01

02
03

04

All dimensions ot be be checked on site prior to manufacturing. Size (W x H)
Glazing is to be free of embossed or transfer motifs unless required by

window manufacturer, supplier, certifier or other. If required, allow for

transfer motifs, 10mm wide band of frost tint with semi circular ends set

in 60mm from window or door styles, positioned at typical motif height.

Contractor to ensure motifs are not embedded within glazing,

Door and Window Schedule shall be read in conjunction with

Architectural Drawings. Any variations from this schedule must be

notified to the Architect prior to ordering

Window & door sizes are nominal. Contractor to ensure windows and

doors are fabricated to match exact framing / surround dimensions and

allow for packing out of walls to accommodate door / window frame

depths.

Contractor to ensure that all window & door head heights are equal .
distance above finished floor level unless otherwise noted Elevation

Al fixings of windows and doors to be 316 grade stainless steel.

All door sills to be set down unless noted otherwise. Contractor to allow
for set down to timber joists & concrete slabs to ensure all doors opening
onto external spaces finish flush with internal finished floor level.
Scheduled door heights do not allow for set downs

Stacking doors to stack so that the are flush with the jamb offering full
egress opening.

Where window openings occur over 1m above finished ground and do
not have a balustrade the opening of the window must be limited to
100mm above finished floor level to allow for compliance with NCC
where applicable.

Where the floor below the window is more than 2m above the surface
beneath the window is to be restricted or screened so a 125mm diamater
sphere cannot pass through. The device or screen must be able to
withstand an outward horizontal force of 250N. Where 102mm louvres
used, louvre system to withstand this horizontal force also.

ALL WINDOW AND DOOR DETAILS ARE TO BE CONFIRMED WITH
NOMINATED SUBCONTRACTOR PRIOR TO DESIGN FABRICATION. — Glazing

Operation Type

 

 

neral Notes to Internal Windows & Doors

Al dimensions ot be be checked on site prior to manufacturing. Finish
All hardware to be satin chrome or stainless steel finish

Door and Window Schedule shall be read in conjunction with
Architectural Drawings. Any variations from this schedule must be
notified to the Designer prior to ordering

Contractor to ensure that all window & door head heights are equal
distance above finished floor level unless otherwise noted

Hardware Set

Notes

Windows & Doors

01

02

03

04

Aluminium Joinery:

Commercial/architectural series aluminium framed sections. Preference
throughout is for slim line frames, maximising glass area

Finish: Powdercoated aluminium - high durability finish generally,
Colour: Black Matt TBC

Note: Contractor to advise Architect if different section is required to
achieve the type and size of glazing item.

Glazing:

Viridian ‘Comfort Plus’ generally tbc. All full height windows and doors to
be ‘Grade A’ toughened safety glass (tbc to sub contractors design and
relevant australian standards),

Finish: Clear (unless noted otherwise)
Note: Design in accordance with Engineers Documentation.
Louvres:

All louvre windows to be by 'Breezeway’. Contractor is to ensure louvre
blades are 102mm wide to comply with NCC 2016.
Insect Screens:

Fit fibre glass insect screens to all operable windows
Where nominated in schedules as 'rectractable' allow for centor
rectractable insect screens integral with door jambs

Door Hardware General Notes

01
02

03
04
05

06

———

\ Ss

NX

All locks to be keyed alike.

All hardware to be supplied complete with striker plates, escutcheons ete
as required.

All hardware to be 316 grade stainless steel unless noted otherwise.
Butt hinges are to be used unless noted otherwise.

Any discrepancies or omissions to be referred to the Architect for
resolution

Swing doors to WC's to be on lift off hinges.

01
5,810x2,100

Sashless sliding window

Clear glass

Powdercoated Aluminium Frame. Colour: TBC

Yet to be selected

02
2,110%2,100

A 20.07.18 AK __| Detailed Design

 

Glass lovres

Clear glass

Colour: TBC

Yet to be selected

Powdercoated Aluminium Frame.

03
3,408x2,550

Casements

NA

Powdercoated Aluminium Frame.
Colour: TBC

Yet to be selected

Detailed Design )

 

parks architects

 

 

Screened Solid Core
Resort Entry Alteration + Swimming Pool Scale 1:1 UU —L__ /— \ \
5 Quamby PI, Noosa Heads QLD 4567 Culgoa Point Beach Resort 106 AK Window Schedule DD 6.1 {
project client job no. drawn drawing dwg no. a, TS

 

Used in these records

About this file

File size
29.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

180078 - Resort Entry Drawing.pdf · 29.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.