Original source · versioned page text
Compiled Reference Document - MCU25/0020 (As Published)
ADG Consulting Pty Ltd 7 Noise & odour management 7.1 Responsibility The Project Manager is responsible for ensuring the appropriate management of noise and odour during dewatering operations. 7.2. Operational policy To minimise noise and odour emissions generated from the site during dewatering. 7.3 Performance criteria The appropriate criteria to measure the performance of dewatering management at the site are provided below. 1. No noise or odour related complaints received from neighbouring residents or the community. 2. No degradation of air quality due to fumes or odours emanating from the dewatering process. 7.4 Implementation strategy Noise and odour emissions will be managed as described in the following sections. 7.4.1 Noise All dewatering equipment must be operated appropriately and maintained in good working order. All dewatering systems and plant must be fitted with the appropriate noise reduction equipment to comply with the performance criteria. Non-complying dewatering plant will be replaced or repaired as necessary. It is proposed to employ noise mitigation strategies including use of electric pumps and dewatering systems rather than diesel powered equipment. Noise attenuation blankets and/or screens (and/or other similar noise attenuation measures) must be installed around noise generating dewatering pumps and equipment where practicable, if required. Noise monitoring equipment (unattended) will be installed by the site manager prior to commencement and monitored for the duration of dewatering, if required. 7.4.2 Odour All dewatering plant must be fitted with the appropriate emission reduction devices. Where practicable, all dewatering plant will be sealed to prevent the release of odours to the atmosphere. Fine mist odour control sprays may be applied to reduce offensive odours if complaints are received from neighbouring residents. 7.5 Monitoring An inspection of the site and dewatering equipment shall be undertaken daily by the Site Manager to identify the following: — Excessive noise being generated by the dewatering systems and plant; and — Strong or offensive odours being generated by the dewatering equipment and/or extracted groundwater. If required by Council, noise monitoring equipment (unattended, continuous logging) may need to be installed by the Site Manager prior to commencement and monitored for the duration of dewatering. The Environmental Protection (Noise) Policy 2019 (EPP(Noise)) identifies specific acoustic quality objectives (noise criteria) to assist in preventing significant impacts on noise sensitive receptors and as a guide to long-term acoustic quality for sensitive receptors. The primary EPP(Noise) criteria relevant to this investigation is outside a dwelling (i.e. adjacent dwellings), which should not have noise at levels in the daytime or evenings greater than 50dB(A) LAeq, adj,1hr. This means that noise levels in the receiving environment outside of nearby dwellings (i.e. on balconies) should not exceed an equivalent sound energy as would be received from a one hour continuous sound of 50 decibels on the A-weighted scale (adjusted for tonal character perceptible by the human ear). ADG1786.25 Dewatering Management Plan_Rev1_07.10.25 Page 18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.