Information Request
Planning Act 2016
I refer to your application and advise that Council requires further information to satisfactorily
assess the proposal.
1. APPLICATION DETAILS
Application No. MCU18/0078 OPW18/0117
Street Address: 165 Gympie Tce Noosaville Qld 4566
Real Property Description: Lot 2 RP 87781
Planning Scheme: The Noosa Plan (27 November 2017)
2. INFORMATION REQUIRED
The information requested is set out below:
Issue - Landscaping
It is not clear where and how high the retaining wall is within the front 6m setback.
The proposed Archontophoenix Alexandrae has shown are not in accordance with Section 13
of PSP 3 Landscaping plants and guidelines and are not supported.
Information Required
1. Please provide plans which clearly identify where and how high the retaining walls are
within the front setback.
2. Please remove the Alex Palms and if required replace with another local native tree
species in accordance with PSP 3.
Issue – Fire systems
Council’s recent experience with developments of the type proposed (1 unit above the other)
is that ancillary fire systems (booster pumps etc) are required. The need for these ancillary
fire systems may have a significant impact on the development (loss of landscaping) and it’s
appearance from the road.
Information Required
PO Box 141 P. (07) 5329 6500 [email protected]
TEWANTIN QLD 4565 F. (07) 5329 6501 www.noosa.qld.gov.au
Page 1 of 3
Document Set ID: 20589896
Version: 2, Version Date: 29/05/2018 Print Date: 29 May 2018, 10:12 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
Noosa Council documents
3. Provide comment from a suitably qualified person in regard to the potential need for any
ancillary fire systems (booster pumps etc). If the systems are required provided
amended plans that clearly indicate the location and extent of any systems.
Issue – Driveway gate
Council has concerns with the location of the proposed gate on the driveway and the
potential for vehicles waiting to access the site blocking the footpath.
Information Required
4. Delete the gate or alternatively provide amended plans that indicate sufficient distance
(6m minimum) between the gate and the footpath to provide the “holding” area.
Issue – Vehicle manoeuvring
The submitted plans do not indicate the vehicle manoeuvring paths to all spaces. Council
has concerns that some spaces may be difficult to enter and exit. Please note that Council
requires sufficient room for vehicles to enter and exit the site in a forward gear.
Information Required
5. Provide amended plans that clearly indicate the vehicle paths for entry and exit from all
the spaces. The plans must:
a. be for a B99 vehicle as described in AS/NZS2890.1:2004; and
b. consider that the adjoining space is occupied.
6. Provide additional detail and comment on the indicated “car stackers”
Issue – Stormwater discharge
Council has concerns with the potential impacts of the stormwater discharge on vehicles in
Gympie Terrace and pedestrians utilising the crossing point.
Information Required
7. Indicate on the plans the expected discharge rate at each outlet point. Please note that
Council’s maximum discharge rate at any one location is 25l/sec.
8. Provide comment on the potential for the discharge to impact on vehicles in Gympie
Terrace and pedestrians utilising the crossing point.
Issue – Overland flow
The stormwater design includes a drainage line to convey surface runoff from an adjoining
property through the development site to Gympie Terrace. This drainage line will need to be
located within a private drainage easement.
Information Required
9. Indicate on the plans the necessary easement or alternatively:
a. provide certification from the design RPEQ that the development will not create
additional ponding of stormwater on any adjoining property; and
b. delete the drainage line from the plans.
3. DUE DATE FOR RESPONSE TO INFORMATION REQUEST
The due date for providing the requested information is 29 August 2018. Please advise Council
of your response to this information request in accordance with section 13 of the Development
Assessment Rules.
Page 2 of 3
Document Set ID: 20589896
Version: 2, Version Date: 29/05/2018 Print Date: 29 May 2018, 10:12 AM
Page 3
Noosa Council documents
If you do not provide a response before the due date, it will be taken as if you have decided
not to respond to the information request and Council will continue with the assessment of
your application.
4. OTHER DETAILS
You can follow the progress of this application online at www.noosa.qld.gov.au. The “Online
Services” page can be accessed via "Quick Links" on the left hand side of the screen.
Should you have any further queries in relation to the above, please do not hesitate to contact
me on the number above.
Yours Faithfully
Glen Conforti
Development Planner
Page 3 of 3